This section describes the function (briefly), the setting-up procedure and the wiring connections
for each MTL5500 unit. For a fuller functional description and a detailed technical specification,
refer to the individual datasheets, which can be found on our website at http://www.mtl-inst.com
or in the current MTL IS catalogue.
If a fault is suspected, first check that the power LED is lit (not applicable to loop-powered
devices). If necessary, check that all signal and power plugs are properly inserted, that no wires
are loose and that the unit is mounted correctly. If operation is still suspect, the unit should be
replaced with a serviceable unit.
There are no replaceable parts inside MTL5500 units, so any that appear to be inoperative should
be returned to the manufacturer/supplier for repair or replacement.
The rest of this section is divided into sub-sections based upon the type of module, as follows.
6 .1
6 .2
6-3
6 .4
6 .5
6 .5
6 .7
6 .8
6 .9
Note: Any LED indicator provided on the modules will display in the following colours:
18

UNIT DESCRIPTIONS, SETTING-UP AND CONNECTIONS

When disconnecting units for maintenance purposes, take care to
segregate hazardous and safe-area cables.
• Short circuit hazardous-area cable cores to an IS earth or insulate and
• Insulate and secure safe-area cables. If testing a unit 'in situ' note that
the test equipment used MUST be intrinsically safe.
Digital Input modules
MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514-T,
MTL5514D, MTL5516C, MTL5517
Digital Output modules
MTL5521, MTL5521 -T, MTL5522, MTL5523, MTL5523V, MTL5523VL, MTL5524,
MTL5525, MTL5526
Vibration, Pulse and Foundation Fieldbus modules
MTL5531, MTL5532, MTL5533, MTL5553
Analogue Input modules
MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5541S-T, MTL5544, MTL5544A,
MTL5544AS, MTL5544D, MTL5544S
Analogue Output modules
MTL5546, MTL5546Y, MTL5546Y-T, MTL5549, MTL5549Y
Fire and Smoke interface modules
MTL5561
Temperature Input modules
MTL5573, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, MTL5582, MTL5582B
General modules
MTL5599, MTL5991
PCS45/PCL45USB configurator for MTL temperature converters
LED label
PWR (power)
STS (status)
LFD (line fault)
FLT (fault)
OPx (o/p status)
WARNING
secure the ends.
LED colour
Green
Yellow
Red
Red