Omron FZ2-30 10 Series Instruction Manual page 9

Vision sensor
Table of Contents

Advertisement

Parallel Interface
PNP I/O type FZ2-305-10/FZ2-355-10/FZ2-505-10/FZ2-555-10
FZD-505-10/FZD-555-10
Internal Specifications
[Input] signals: RESET, DI0 to DI7, DSA
Input voltage
12 to 24 V DC ±10 %
ON current *1
5 mA min.
ON voltage *1
8.8 V min.
OFF current *2
0.5 mA max.
OFF voltage *2
1.1V max.
ON delay
5 ms max.
OFF delay
0.7 ms max.
Internal circuit
Input terminal
COM IN
*1 ON current/ON voltage
This refers to the current or voltage values needed to shift from the OFF → ON state. The ON voltage value is the potential
difference between each of the input terminals and COM IN.
*2 OFF current/OFF voltage
This refers to the current or voltage values needed to shift from the ON → OFF state. The OFF voltage value is the potential
difference between each of the input terminals and COM IN.
[Output] signals:
BUSY, RUN, OR, GATE, ERROR,
DO0-15, READY
Output voltage
12 to 24 V DC ±10 %
Load current
45 mA max.
ON residual voltage
2 V max.
OFF leakage current
0.2 mA max.
Internal circuit
I/O Connector
No.
Signal name
Wire color Mark (red)
I/O Connector wiring is the same as NPN I/O type.
[Input] signals: STEP
Input voltage
ON current *1
ON voltage *1
OFF current *2
OFF voltage *2
ON delay
OFF delay
Internal circuit
[Output] signals: When STGOUT0-3 are not used,
Output voltage
Load current
ON residual voltage
OFF leakage current
Internal circuit
COM OUT
Load
Output terminal
Function
No.
Signal name
12 to 24 V DC ±10 %
5 mA min.
8.8 V min.
0.5 mA max.
0.8 V max.
0.1 ms max.
0.1 ms max.
Input terminal
COM IN
connect the COM IN terminal.
12 to 24 V DC ±10 %
45 mA max.
2 V max.
0.2 mA max.
Wire color Mark (red)
Function
COM OUT
Output terminal
Load
COM IN
8

Advertisement

Table of Contents
loading

Table of Contents