EnGLIsH
nOTE: This setting also controls the level of suction. This
is very useful in applications where the vacuum creates
unacceptable levels of drag to the work piece.
5. Follow the direction under connecting to Power Tools to
connect to the power tool to be used.
nOTE: Refer to Pairing the Dust Extractor with a Tool using
Wireless Tool Control™ Mode to use the dust extractor with a
Wireless Tool Control™ equipped tool or remote.

Filter Care

Class H filters must not be cleaned manually. If the filter is
clogged, it must be disposed of.
The filters included with this vacuum are long life filters. To be
effective in minimizing dust recirculation, the filters MUST be
installed correctly and in good condition.

WARNING: Appropriate personal protective equipment
like dust mask and gloves should be used while handling
the filters.

WARNING: Dispose of the used filter in accordance with
the legal regulations.
Hose Diameter Adjustment (Fig. E)
Adjust the three-position switch 
tube) inside diameter size (32mm or 20mm) or accessory
diameter referring to the largest section. The chosen diameter
of the adjustment control must be equal or bigger as the largest
diameter of the used hose/tube/ accessories. The hose supplied
is 32 mm inside diameter. An acoustic alarm will sound if the
flow rate falls below 20 m/s. The system has a time delay to
reduce unintended alarms.
nOTE: Set the hose diameter regulator only to the yellow
marked diameter ranges of the connected suction hose.
If the alarm sounds when there is no apparent blockage:
1. Ensure that the adjustment control is set to the
correct diameter.
2. If the flow rate adjustment is set below the maximum,
increase this level until sufficient flow through the hose
causes the alarm to stop.
3. If the alarm still continues to sound, remove hose and check
that it is clear. Remove and replace dust bag if full or blocked
and check filter condition and replace where necessary.
If the alarm continues to sound contact your local D
service agent.
Connecting to Power Tools (Fig. C, D)

WARNING: Only use the outlet for purposes specified in
the instructions.

WARNING: Before setting the switch to position "Tool
Control", make sure that the connected tool is switched off.

WARNING: The maximum load of the power tool shall
not exceed the rated maximum outlet power rating at the
socket outlet.
nOTE: Some Brushless AC tools can start the Vacuum in auto
mode without turning on the power tool.
1. Plug the vacuum power cord into an appropriate outlet.
30
 16 
to the correct hose (or
WALT
e
2. Turn on/off tool control switch 
position . This allows the vacuum to be turned on and off
automatically by the power tool. The minimum power of
the tool must be larger than 250 watts for the Vacuum to be
controlled via the socket?
nOTE: The vacuum cleaner starts automatically within 0.5
seconds and continues to run for 7  seconds after the power
tool has been turned off. Afterrun can vary when used with
a power generator.
3. To switch back to manual mode, turn the on/off tool control
switch 
 15 
to the ON position 
and the vacuum are turned on and off independent of
each other.
4. Your D
WALT construction dust extractor is fitted with the
e
D
WALT AirLock connection system. The AirLock allows for
e
a fast, secure connection between the suction hose 
power tool. The AirLock connector 
D
WALT compatable tools or through the use of an AirLock
e
adapter (available from your local D
to the Accessories section for detail on available adapters.
nOTE: If using an adapter ensure it is firmly attached to the
tool outlet before following the steps below.
a. Ensure the collar on the AirLock connector is in the
unlock position. Align notches 
connector as shown for unlock and lock positions.
b. Push the AirLock connector onto the adapter
connector point.
c. Rotate the collar to the locked position.
nOTE: The ball bearings inside collar lock into slot and
secure the connection.The power tool is now securely
connected to the dust extractor.
Pairing the Dust Extractor with a Tool using
Wireless Tool Control™ Mode (Fig. A, M)

CAUTION: When the dust extractor is being controlled
with the remote or paired power tool it may start or stop
without warning.

WARNING: Do not attach the remote strap to
moving parts.
To Pair with a D
WALT Remote or Wireless Tool
e
Control™ Tool
1. Turn the on/off tool control switch
2. Press and hold the Wireless Tool Control™ pairing button
the extractor and pull the trigger on the Wireless Tool Control™-
equipped-tool, or press the remote button
Tool Control™ remote
27
3. The LED above the Wireless Tool Control™ pairing button will
be steadily illuminated to indicate a successful pairing.

CAUTION: Do not activate the Wireless Tool Control at the
Tool if the dust extractor hose is not connected to the dust
extraction port of the tool.
nOTE: Only one transmitter can be paired to the DWV905 at a
time. If the unit is already paired the previous transmitter will be
overridden.
 15 
to the ACTIVATION
   
). In manual mode the tool
 25 
connects directly to
WALT supplier). Refer
e
 26 
on collar and AirLock
to the
position.
15
on the Wireless
28
at the same time.
 7 
and
17
on

Advertisement