Symptom
Slow cycle
Rivet stem does not break
Low vacuum
Item numbers in bold refer to assembly drawings and parts lists on pages 2, 4, 5 and 6.
Other symptoms or failures should be reported to your local authorised distributor or repair centre.

8. GENERAL SAFETY DATA

8.1 HYSPIN
VG32 OIL SAFETY DATA
®
8. 1. 1 FIRST AID
SKIN:
Unlikely to cause harm to the skin on brief or occasional contact but prolonged or exposure may lead to
dermatitis.
Wash skin thoroughly with soap and water as soon as reasonably practicable. Remove heavily contaminated
clothing and wash underlying skin.
Launder contaminated clothing.
ORAL:
Unlikely to cause harm if accidentally swallowed in small doses, though larger quantities may cause nausea
and diarrhea.
If contamination of the mouth occurs, wash out thoroughly with water.
Except as a deliberate act, the ingestion of large amounts of product is unlikely. If it should occur, do not
induce vomiting; obtain medical advice.
Take person to nearest medical centre.
EYES:
Unlikely to cause more than transient stinging or redness if accidental eye contact occurs.
Wash eyes thoroughly with copious quantities of water, ensuring eyelids are held open. Obtain medical advice
if any pain or redness develops or persists.
8. 1. 2 DISPOSAL:
Remove all spills with inert absorbent material. Ventilate spill area. Place contaminated materials in
a disposable container and dispose in a manner consistent with local regulations.
Possible Cause
Low air pressure.
Build up of debris inside the Nose
Equipment (1).
Collector Bottle (3) removed or not
fully attached.
Low air pressure.
Fastener outside tool capability.
Incorrect Nose Equipment (1) for
rivet.
Low oil level or air in oil.
Stem Collector (3) removed or not
fully attached.
Stem Collector (3) full of stems.
Low air pressure.
Remedy
Adjust air pressure to within
specification.
Service and clean Nose Assembly (1).
Check Collector Bottle.
Adjust air pressure to within
specification.
Refer to Placing Tool Rivet Range &
Nose Equipment table.
Refer to ProSet Nose Equipment
Manual 07900-09412. Select and
install correct nose equipment
Prime tool.
Check Stem Collector.
Empty Stem Collector (3)
Adjust air pressure to within
specification.
E N G L I S H
Page Ref.
9
13, 16
15
9
11
17
12
12
9
21