Lincoln Electric INVERTEC 400TPX Operator's Manual page 18

Hide thumbs Also See for INVERTEC 400TPX:
Table of Contents

Advertisement

Torch control functions UP/DOWN
The torch control functions are available if up/down
module on the torch is assembled on torch and "Option
50" is enabled in the Setup Menu. There are two functions
available:
Option 50 "Cur" change set current value:
Three operating modes, corresponding to different states
of the machine, are identified:
Before welding: pressing the UP or DOWN key
causes a change of value of the Set current
While welding: pressing the UP or DOWN key causes
a change of value of the Set current during all phases
of welding process except during the start functions,
where the UP/DOWN function is masked.
Pre/post Flow: pressing the UP or DOWN key causes
a change of value of the Set current.
The change will be realized in two ways depending on
pressed button time:
Step function
Pressing the UP/DOWN button for a minimum time of
200ms and releasing it, causes the set current
raises/falls of 1A.
Ramp function
Pressing the UP/DOWN button for a time greater
than 1 sec., the set current start to increase/decrease
with a (5A/s) ramp. If press for more then 5 ses
increase/decrease with a ramp of (10A/s).
The current ramp will end when the UP/DOWN button
previously pressed is released.
When a remote (pedal or RC-pot) device is present,
depending on welding process selected, the UP/DOWN
behavior is different.
SMAW:
In SMAW welding mode, the remote device set the
amperage setting in the whole range, bypassing the main
control knob in front User interface. In that case the
signals coming from UP/DOWN are ignored.
GTAW:
In GTAW mode of welding, the remote device set the
percentage of the main set delivered by the machine.
Regulating the main amperage, the UP/DOWN with
remote device will work as described above.
Option 50 "Job" Change memory:
By pressing torch buttons user will be allowed to change
over settings stored in memory locations from 1 to 9. The
feature is not available during welding.
English
Setup menu
The setup menu contains more parameters that are
hidden from the main control panel functionality.
To enter the Setup menu:
Push and hold "SEL" and "MODE" pushbuttons
Keep "SEL" + "MODE" pushed until the displays show
Then release the SEL" pushbutton
now is shown the option
number "00"
Select the desired option: on the left display is shown the
then press "SEL" to confirm
ON / OFF (or 1 / 2 / 3 / 4 only for option 40)
Now enable, disable or change the option value: on the
right display is shown the option status
Save the desired option by pressing the "SEL" pushbutton
To exit the setup menu select the 00 option and keep the
SEL button pushed for 5 seconds until normal operation is
16
+
"SET UP"
empty display
01  99
option number
ON / OFF
resumed.
English

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents