System Configuration and Functions

Lockout Reset Function

Easy Type
Basic Type (basic system)
Basic Type (muting system)
When the cause of the lockout is removed, you can release the lockout by using either of the following
methods. *1
•Cycle the power back ON
•Reset input
Resetting methods differ as follows depending on the system used.
Easy Type
Basic Type (basic system)
Manual reset
Basic Type (basic system)
Auto reset
Basic Type (muting system)
*1. When there is an input wiring error at startup, a lockout reset does not work. Fix the wiring error
and then turn ON the power again.
F3SJ-E/B
20
User's Manual
System
Apply a voltage of 0 V to 3 V to the test input line (black) for 1 s or longer, and then
open the input line or apply 1/2 Vs to Vs again.
Apply a voltage of 0 V to 3 V to the reset input line (yellow) for 1 s or longer, and then
open the input line or apply 1/2 Vs to Vs again.
Open or apply 1/2 Vs to Vs to the reset input line (yellow) for 1 s or longer, and then
apply a voltage of 0 V to 3 V again.
Lockout reset