Diagnostic stages

High gearmotor amps – Stage 1
The HI AMPS error and TIME DELAY LEDs are on indicating that the control board has sensed an over-torque
condition at the P4 terminal (more than 3A from the gearmotor) or no current draw (0A) and shut the ice machine
down (strike one). The HI AMPS and TIME DELAY LEDs will remain on for 60 minutes after an over-torque
condition has occurred. The ice machine will remain off as long as these two LEDs are on. After the 60 minute time
delay, these LED lights turn off, and the control board will try to go through a normal start-up sequence.
RED
Start
Relay
3
YELLOW
R
S
C
Gearmotor
A B C D
Water Sensors
28
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz
T.O.L.
R
S
C
Compressor
2
1
Start
Relay
5
Compressor
Electrical Box
WHITE
Drain
Fill
4
Valve
Valve
2
BLACK
Bin T-Stat
Fan
WHITE
N
N
P15
L1
BLACK
L1
HI PRS
RED
P6
P21
BROWN
P20
P19
BLACK
P3
WATER LEVELS
P22
BLUE
P4
AUGER
High
Pressure
Switch
POWER
LOW BIN
MAKING ICE
SLEEP CYCLE
TIME DELAY
LOW WATER
1 2 3 4 5 6 7 8
MAINTENANCE
RESET
SERVICE
HI AMPS
HI PRESSURE
BIN
P11
CLEANER FULL
Clean Switch