Fan Removal - Follett L90815 Manual

Ice and water dispensers 230 v 50 hz, 220 v 60 hz
Table of Contents

Advertisement

Fan removal

1. Remove 4 fan mounting screws and 3 drain
tubes from bracket.
2. Rotate fan mounting bracket toward back of unit
and pull fan assembly toward front of unit.
Fig. 18
Fig. 19
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz
REMOVE DRAIN TUBES
FROM DRAIN CAP.
REMOVE DRAIN CUP
AND CAP.
REMOVE FAN BASE
MOUNTING SCREWS.
ROTATE BASE OF FAN
TOWARDS BACK OF UNIT.
MOVE FAN AWAY FROM
CONDENSER.
MOVE FAN TOWARDS
FRONT OF UNIT TO
COMPLETE REMOVAL.
39