9.1.3 Specifications of standard wiring components
9.2 To connect the electrical wiring to the outdoor unit
RXTM-R_RXTP-R_ARXTP-R_RXTA-B
R32 split series
4P518023-11H – 2021.03
Wire type
Stranded conductor wire
with round crimp-style
terminal
Tightening torques
Item
M4 (X1M)
M4 (earth)
▪
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
Component
Power supply cable
Interconnection cable (indoor↔outdoor)
Recommended circuit breaker
Residual current device
1 Remove the service cover. See
2 Strip insulation (20 mm) from the wires.
c b
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
1-3
Voltage
Phase
Frequency
Wire sizes
"6.2.2 To open the outdoor
9
Electrical installation
|
Installation method
a
b
c
B
Tightening torque (N•m)
1.5~1.6
1.4~1.5
220~240 V
1~
50 Hz
3-core cable
2(a)(b)
2.5 mm
/ 4.0 mm
(a)
H05RN-F (60245 IEC 57)
(b)
H07RN-F (60245 IEC 66)
4-core cable
2
1.5 mm
~2.5 mm
applicable for 220~240 V
H05RN-F (60245 IEC 57)
16 A
MUST comply with applicable
legislation
4
unit" [
Installer reference guide
2(b)
2
and
28].
49