3.
Turn ON the sensor to perform beam alignment.
Move the emitter from side to side (Figure 3) to align it to a center position where the stable-state
indicator (STB) is turned ON while checking the top beam state and bottom beam state with the top-
beam-state indicator (TOP) and bottom-beam-state indicator (BTM). (Figure 4)
Next, move the receiver from side to side (Figure 3) to align it to a center position where the stable-
state indicator (STB) is turned ON. (Figure 4)
Figure 3
- Confirm that there is no interrupting object in the detection zone before adjusting beams.
- If the stable-state indicator (STB) does not turn ON despite performing alignment, check if the mounting surfaces of
the emitter/receiver are parallel, and if the mounting height of the emitter/receiver is appropriate. Using optional
Laser Alignment Kit (F39-PTJ) makes alignment easier.
4.
Tighten the lightly tightened hexagon socket head cap screws (M3 x 6) of the Top/Bottom Brackets.
(Figure 5)
Tighten the hexagon socket head cap screws (M3 x 6) with the torque at 0.54 N•m (recommended).
Backside mounting
Tighten
securely
Tightening screws with a torque that considerably exceeds the recommended torque may cause failure.
Mounting is complete.
Emitter
EMITTER
Side mounting
Tighten
securely
Figure 5
Wiring/Installation
Receiver
TOP indicator
(Blue)
STB indicator
(Green)
BTM indicator
(Blue)
RECEIVER
Figure 4
Enlarged view
Tighten
securely
Hexagon socket head
cap screw (M3 x 8)
E