Wiring/Installation

When Using Replacement Brackets

 Backside mounting
Bracket mounting procedure (Mounting) p.71
If the protective height is more than 1105 mm, use Intermediate Brackets of the quantities and locations according to
the dimensions described on page 51 "When Using Top/Bottom and Intermediate Brackets". If the brackets described
above are not used, ratings and performance cannot be met.
F3SJ-E/B
64
User's Manual
43
Replacement Bracket
(F39-LJB4)
13
Replacement Bracket
(F39-LJB4)
M3 x 6 screw
Dimensions A to C
A
C+159
B
C+86
C
4-digit number of the type name (protective height)
30
19
6.5
M3 x 6 screw
30
19
4-M5
[ Unit : mm ]