Omron Sti F3SJ-E N25 Series User Manual page 42

Table of Contents

Advertisement

System Configuration and Functions
 Using muting function
Turning muting inputs 1 and 2 ON sequentially enables muting function.
When a muting lamp is required as a result of a risk assessment, connect a muting lamp to the
auxiliary output line.
<Start conditions>
If both of the following conditions are present for the F3SJ-B, muting is activated.
1. No interrupting object is found in the F3SJ-B's detection zone, and safety output is ON.
2. After muting input 1 is turned ON (connected to 0 V to 3 V), muting input 2 is turned ON (connected
to 0 V to 3 V) within the muting input time limit of T1min to T1max (0.1 to 3 s).
Muting function can be enabled in up to 0.15 s after condition 2 is satisfied. When condition 1 is
satisfied but time condition of 2 is not, a muting sequence error occurs and emitter's muting error
indicator blinks. However, when there is a muting error, the F3SJ-B safety function operates and
normal operation continues.
For muting error indication, see page 117 .
Muting error can be released by any of following conditions:
1. Correct muting initial condition continues for 0.1 s or longer. *1
2. Power cycle under muting input 1 and 2 OFF state.
*1. The correct initial muting condition is shown as follows.
• Safety output of the light curtain is ON.
• Muting input 1 and 2 are OFF.
<End conditions>
If either of the following conditions is satisfied, the muting state is released.
1. Muting input 1 or 2 turns OFF for T3 (0.1 s) or longer.
2. The muting continuation time exceeds the muting time limit of T2 (60 s).
Muting input 1
Muting input 2
Muting state
Auxiliary output
F3SJ-B Unblocked
/Blocked
Safety output
F3SJ-E/B
26
User's Manual
ON
OFF
T1min to T1max
ON
OFF
0.15 s max.
Enabled
Disabled
Blinking
OFF
Unblocked
Blocked
ON
OFF
T3 max.
T3 max.
T2 max.
1 Hz Blinking

Advertisement

Table of Contents
loading

Table of Contents