Installing The Indoor Unit; Installing The Outdoor Unit - Samsung AR7000 Manual

Table of Contents

Advertisement

Installing the indoor unit

Perform the following work on the area where gas leak test was done priory.
After checking for gas leaks in the system, insulate the pipe, hose and cables.
Then place the indoor unit on the installation plate.
1. To minimise condensation, wrap foam insulation (as shown in the figure) on a
part without insulation on the end of the pipes.
2. Cover the pipe, cable and drain hose with vinyl tape.
3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part
of the indoor unit carefully so it does not project from the rear of the indoor
unit.
4. Hook the indoor unit to the installation plate and move the unit to the right
and left until it is securely in place.
an installation plate.
5. Wrap the rest of the pipe with vinyl tape.
6. Attach the pipe to the wall using clamps (optional).

Installing the outdoor unit

Install the outdoor unit level on a stable base to help avoid the generation of noise and
vibration, especially when installing the unit close to another structure..
If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an
appropriate support (wall or ground).
1. Place the outdoor unit as indicated to ensure correct airflow.
2. Fix the outdoor unit in level to an appropriate support using anchor bolts.
3. If the outdoor unit is exposed to strong winds, install shield plates around the
outdoor unit so that the fan can operate correctly.
Outdoor unit installed on the wall by bracket
vibration transferred by outdoor unit towards wall.
AR7000 CV HP_IB&IM_DB68-05637A-00_EN.indd 53
Connecting wires
Soft rubber designed to cut off
vibration from rack to wall.
(not supplied with product)
English-53
Insulation
Pipes
Installation
plate
Connecting
pipes
Vinyl tape
Drain hose
'X' mm
Rubber leg
Model
X
Y
2.01ft
1.04ft
AR09/12KSWS
(612mm)
(317mm)
AR18KSWS
2.16ft
1.12ft
(660mm)
(340mm)
AR09/12KSWD
2.12ft
1.12ft
AR24KSWS
(340mm)
(645mm)
Designed to cut off residual vibration
from outdoor unit to rack.
(not supplied with product)
2015/10/12 15:43:20