Instructions for the Installer

The instructions given below are designed
specifically for a qualified installer and should
aid him or her to perform all installation,
adjustment, and maintenance operations with
absolute precision and in compliance with all
current legislation and regulations. We
strongly recommend that all operations for
the installation of your cooker be carryed out
by Qualified Personnel in accordance with
existing rules and regulations.
Electrical connection
Prior to making the electrical connection, make sure that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric load of the
oven (see rating plate);
— your domestic wiring system has an efficient
earth connection in compliance with rules and laws in
force;
— the wall socket or the omnipole switch used for
the electrical connection can easily be reached after the
oven is built in.
This appliance is delivered without an electric supply cable,
therefore, you will have to fit to it a supply cable with standard
plug, suitable for the total electric load shown on the rating plate.
The plug is to be inserted into a suitable wall socket. If you
require a direct connection to the electric network (mains), it will
be necessary to fit between the appliance and the mains an
omnipole switch, with a minimum gap between contacts of 3
mm, suitable for the required load and in compliance with rules
in force. The green & yellow ground wire must not be interrupted
by the switch, and should be 2-3 cm longer than the phase and
neutral wires. The supply cable must in all cases be laid out in
such a way as to ensure that it does not reach at any given
point a temperature 50°C higher than the ambient temperature.
Suitable power supply cables are the following types,
considering the respective necessary section of cable: H07
RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90),
H05 BB-F.
Connecting the terminal board
The appliance incorporates an easily accessible 6-pole terminal
board whose jumpers (bridges) are already pre-set for operation
on 400 V tri-phase with neutral wire (Fig. 8). In case a different
mains voltage is present, the jumpers on the terminal board must
be rearranged as shown in the diagram (Fig. 9). The ground
cable must be connected to terminal
supply cable to the terminal board, secure it with a junction
clamp.
Electrical connection with the hob
This oven can be connected to hobs indicated in the
paragraph "Technical data". The socket for connecting the
hob is located at the top of the oven cabinet. The hobs
come complete with connecting leads for the hot plates/
heat areas and ground cable; these leads feature plug-in
connectors. Connection of the hob to the oven is carried
out by plugging-in these connectors to the corresponding
oven socket.
The plug-to-socket connection design is such as to prevent
possible wrong plugging-ins.
The Manufacturer disclaims any liability in case
these accident-preventing rules are not observed.
. After connecting the
Fig. 8
1 2 3 4 5
230V 3~
Ø 4x2,5mm²
L1
1 2 3 4 5
230V 1~
Ø 3x2,5mm²
L1
1 2 3 4 5
400V 2N~
Ø 4x2,5mm²
L1 L2
1 2 3 4 5
400V 3N~
Ø 5x1,5mm²
L1 L2 L3 N
Fig. 9
L2
L3 PE
N
PE
N
PE
PE
33