2.0

System Chart

Minimum Hours of Standby
Battery
D8103 Enclosure
D8108A Enclosure
D8109 Enclosure
D122 and D122L Dual Battery
Harness
D125B Class B, Style A
Powered Loop Interface
D129 Class A, Style D Initiating
Module
D126/D1218 Battery
D127 Reversing Relay
D928 Dual Phone Line Module
D161 Telephone Cord
D185 Auxiliary Interface Kit
D192A/D192C/D192G Class B,
Style W Bell Circuit Supervision
Smoke Detector Base
D268/D269H Independent Zone
Control
Indicating Device
D461 Pull Station
D1255/D1260 Command Center
D1256
D1257
D1640 Transformer
D8004 Transformer Enclosure
D8122 Derived Channel S.T.U.
D8125 Class B, Style 3.5
POPEX Module
D8125MUX
D8127T/U & D9127T/U Class B,
Style A POPIT Modules
D8128D OctoPOPIT
D8129 OctoRelay
D8130 Release Module
D8132 Battery Charger
D9131A Parallel Printer Interface
No = Not acceptable for this application.
# - D125B and D129 required to connect fire alarm initiating devices to zones 1-8. D125B provides two powered loops for connecting listed
2-wire smoke detectors. D129 provides two non-powered Class A initiating circuits.
1+ = One or more required for this application. Consult the appropriate standard.
1++ = At least one detector required. You can substitute other 2-wire detectors listed for use with the D125. You could also use the D262
with the D270 4-wire base and a listed power supervision relay.
** = Listed bell (siren) housing required for burglary alarm bell or siren.
[Empty Cell] = Not used for this application.
© 2003 Bosch Security Systems
24 +
24 +
4
4
4
4
mins
mins
alarm
alarm
Choose one.
D101 lock required for
enclosure.
Calculate current draw to determine if second
battery is required.
Opt.
#
#
Opt.
#
#
1+
1+
1+
1+
Opt.
No
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Required to connect panel to RJ31X
TelCo. Block
Opt.
Opt.
Opt.
Opt.
1++
1++
Optional, only connect to zones 1 to 8.
1+
1+
1+
Opt.
Optional, may be required by job specifications
and/or Authority Having Jurisdiction.
1+
1+
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Required for all applications.
Opt.
Opt.
Opt.
Opt.
Optional, contact TelCo. for availability of derived
channel service.
Required for D8127T/U and D9127T/U POPITs.
Required for MUX devices. Refer to section 4.2.
Opt.
Opt.
Opt.
Opt.
Opt.
No
Opt.
Opt.
Optional, for remote annunciation of system
functions.
Optional
See Current Rating Chart and Standby Battery
Requirements to determine if system requires a
D8132 Module for increased battery standby.
Optional, use with parallel printer to print events
from panel log locally.
Req. = Required for this application.
Table 1: UL System Chart
D7212G Approved Applications Compliance Guide
4
4
No
No
Req.
Req.
No
No
Opt.
Opt.
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
**
**
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt. = Optional for this application.
Page 7
D7212G
System Chart
4998138560C

Advertisement

Table of Contents
loading

Table of Contents