Functions Programming - CAME VLR01DX Installation Manual

Shutter operator
Hide thumbs Also See for VLR01DX:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 24

Functions programming

Before programming functions, release the gearmotors, manually close the shutter leaves and re-lock the gearmotors.
* Up to 25 codes can be stored between the transmitters and weather stations for the operator wireless control.
Function description
Travel programming.
In the case of a single leaf, connect the
operator to MOTOR2.
Close the leafs before proceeding.
Partial travel programming.
It is programmable between the
default value 10% (minimum) and 50%
(maximum) of the total travel
Only consider the first leaf's opening
angle. At the first maneuver, the second
leaf will position as the first one.
Second leaf delay programming.
By default it is set to 2 seconds.
Maneuvering speed programming.
By default it is set at 70% of the
potential.
Slow-down speed programming
By default it is set at 40% of the
potential.
Sensitivity programming.
By default, the stroke reversal in the
presence of an obstacle is set to
½ seconds.
Hold-to-run Action activation/
deactivation..
By default, this function is deactivated.
If activated, it is not possible to
activate the partial opening
All memorized transmitters (except the
weather stations) are disabled.
Partial opening activation/
deactivation.
By default, this function is deactivated.
If activated, it is not possible to
activate also the hold-to-run function.
Slowed down start activation/
deactivation.
By default, this function is deactivated.
How to program it
Hoe to arrange the
DIPs
1
2
3
4
ON OFF ON OFF PROG on the card.
The leaves will perform
a series of maneuvers to
establish the limit switch
points.
If the calibration is not successful, the LED flashes quickly and the
buzzer beeps 4 times. It is possible to interrupt the calibration pressing
the PROG key.
OFF ON ON OFF Bring the leaf to the desired
partial opening position.
PROG on the card.
If the partial opening angle does not come within the minimum
and maximum default-set limits upon sending the next command the
opening angle will automatically set to the closest limit level.
ON ON ON OFF Press PROG on the card up
to the desired value, based
on the beeps emitted by the
buzzer.
OFF OFF OFF ON Press PROG on the card up
to the desired value, based
on the beeps emitted by the
buzzer.
ON OFF OFF ON Press PROG on the card up
to the desired value, based
on the beeps emitted by the
buzzer.
OFF ON OFF ON Press PROG on the card up
to the desired value, based
on the beeps emitted by the
buzzer.
ON ON OFF ON PROG on the card.
OFF OFF ON ON PROG on the card.
ON OFF ON ON PROG on the card.
→ The red LED flashes.
→ Once the calibration is done the
buzzer beeps once.
→ The red LED flashes.
Once memorized, the buzzer
emits a beep.
→ 1 beep = 2 seconds
2 beeps = 4 seconds
3 beeps = 6 seconds
4 beeps = 8 seconds
→ 1 beep = 70%
2 beeps = 80%
3 beeps = 90%
4 beeps = 100%
→ 1 beep = 40%
2 beeps = 50%
3 beeps = 60%
4 beeps = 70%
→ 1 beep = ½ seconds
2 beeps = 1 second
3 beeps = 2 seconds
4 beeps = 3 seconds
→ 1 beep = activation
2 beeps = deactivation
→ 1 beep = activation
2 beeps = deactivation
→ 1 beep = activation
2 beeps = deactivation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlr01sxVlr02

Table of Contents