Quadra-Fire CASTILE Owner's Manual Installation And Operation page 15

Pellet insert
Table of Contents

Advertisement

R
10. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
Frequency: Yearly or more frequently depending on
ash build-up.
By: Qualified Service Technician/Homeowner
Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
The products of combustion will contain small particles
of fly ash. The fly ash will collect in the exhaust venting
system and restrict the flow of the flue gases.
At start-up if there is incomplete combustion, or if there
is a shutdown or incorrect operation of the appliance it
will lead to some soot formation. This will collect in the
exhaust venting system.
The venting (chimney) system may need to be cleaned at
least once a year or more often depending upon the qual-
ity of your fuel or if there is a lot of horizontal pipe sections.
Ash will build up more quickly in the horizontal sections.
11. Door Latch Inspection
Frequency: Prior to heating season or monthly during
heating season
By: Homeowner
The door latch is non-adjustable but the gasketing between
the glass and firebox should be inspected periodically to make
sure there is a good seal.
12. Cleaning Combustion Blower - Requires No
Lubrication
Frequency: Yearly or as needed
By: Qualified Service Technician
Task: Contact your local dealer
13. Cleaning Convection Blower - Requires No
Lubrication
Frequency: Monthly or every 25 bags or more fre
quenly depending on operating environ-
ment
By: Qualified Service Technician
Task: Contact your local dealer.
October 27, 2011
14. Preparing Firebox for Non-Burn Season
Frequency: Yearly at the end of the heating season
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove all ash from the firebox and vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
• Use the Touch-Up paint supplied with the appliance;
or;
• Purchase paint from your local dealer.
• Must use a high-temperature paint made specifi-
cially for heating appliances.
7069-101B