Install the Device
2. Connect the other end of the power cord to an AC-input power source.
3. Verify power supply operation by checking if the respective power supply front panel LED (PS0 or PS1)
is green.
4. If the LEDs indicate a power problem, see Troubleshooting for troubleshooting information.
5. If you are also connecting a redundant AC power supply, repeat these steps for the second power source.
Note
The operating voltage range is 90V-265VAC, 50/60Hz.
Install the DC Power Cables
Note
Note
If you are connecting a redundant AC power supply, ensure that each power supply is connected to a
separate power source in order to prevent power loss in the event of a power failure.
When installing DC power supply, use 14AWG for longer cables and 14-16AWG for shorter cables,
90°C temperature rated cable. The recommended cable length is three meters maximum from source.
• Always ensure that the building's installation for short-circuit (overcurrent) protection does not
exceed 15A.
• We recommend you to use a circuit breaker or a fast acting fuse with a maximum DC rating, based
on the router variants for over current protection.
Table 3: Main Circuit Breaker Power Ratings
Router
• N540X-6Z18G-SYS-D
• N540X-8Z16G-SYS-D
• N540X-4Z14G2Q-D
N540-6Z18G-SYS-D
Install the DC Power Cables
DC Power Rating
10A
6A
Install the Device