Standard System (2) Station-To-Station Wiring - Aiphone GH SERIES 0207 AIC Installation And Operation Manual

Apartment intercom system
Table of Contents

Advertisement

4-2
a
e
1P
NP
SW1
A
B
c
IN OUT
B1B2 B1B2
1P
NP
SW1
B
A
IN OUT
B1B2 B1B2
[1]
SW1
GH-1KD
B
A
IN OUT
B1B2 B1B2
GH-VBC
1P
b
NP
GH-BC
1P
NP
[4]
b
c
1P
NP
GH-1AD
IN OUT
R1R2 R1R2 C CE K KE
R1, R2
GH-1KD
IN OUT
R1R2 R1R2
C CE K KE
1P
NP
[2]
K
KE
GH-1KD
IN OUT
R1R2R1R2
C CE K KE
[2]
1P
1P
NP
NP
SW1 A
B
Do not remove the wires (For end users)
IN
R1 R2 R1 R2 C
IN OUT
R1R2R1R2
C CE K KE
[2]
[3]
GH-RY
B
AC
4-1
Standard System (1)
[1] Entrance Station
[2] Door release timer (set to "M" at time of shipment)
• Set the duration for the door release function when the door
release button is pressed.
[0.5] - [20]: 0.5 secs - 20 secs
[20] - [M]: Activates while the button is pressed.
[3] Setting switch (GH-DA/A)
• SW2: 1: Setting switch for camera entrance station monitoring
function (set to OFF at time of shipment)
ON (Up): Monitored.
OFF (Down): Skipped at time of entrance station monitoring.
• SW2: 2 - 4: Entrance station number setting switch (set to #1 at
time of shipment)
When installing multiple entrance stations, make sure to set
the GH-DA/A ID numbers (SW2).
[4] External signaling relay GH-RY
For details, see 4-5.
[5] Door release relay contact
Less than AC/DC 24 V, 4 A (resistance load)
PT: AC Transformer
[6] Security guard station GH-MK
[7] Setting switch (GH-MK)
• SW1: 1: Password reset switch
Set the password reset switch to ON for 2 seconds or more
during standby will reset the password (set to "∗1111" at time
of shipment).
• SW1: 2, 3: Unused switch
• SW1: 4: Security guard station number setting switch (set to #1
at time of shipment)
When installing two security guard stations, make sure to set
the ID numbers (SW1).
[8] Doorbell button
[9] Power supply PS-2410LC, PS-2410LD, PS-2410DIN
[10] Video Bus control unit GH-VBC (SW: STD)
[11] Video Bus control unit GH-VBC (SW: EXP)
• To use GH-VBC as an extension adaptor, set the setting switch
to "EXP". Connect only "IN1" terminal at input side.
[12] Bus control unit GH-BC
[13] Distribution terminal (junction): Not included
0.65 10 9
OUT
CE
K KE
NP: Non-polarized
4-2

Standard System (2) Station-to-Station Wiring

[1] Residential station GH-1KD, GH-1AD
• There can be a maximum of 25 stations per trunk.
• For the terminating residential station GH-1KD, set the setting
switch (SW1) to "A".
[2] Short lead
• To use the emergency alarm switch (see 11-7 for details),
disconnect the short lead and connect the switch.
[3] External signaling relay GH-RY
For details, see 4-5.
The separate option connecter is required.
[4] Doorbell button
1. Do not mix station-to-station wiring with homerun wiring.
2. Station-to-station wiring is not possible for GH-1MD.
NP: Non-polarized
- 19 -