Service manual
Switch & AC motor replacement - fitting
33
65 Attach the motor/PCB loom
assembly bracket to the motor
using the two Torx T-20 screws.*
Attach the Live and Neutral wires
to the motor.
Note: the Neutral wire should sit
behind the PCB.
*Models with finger tip controls
only.
66 Carefully feed all the wires up
through the underside of the
motor mount. Locate the loom
grommet into the mount.
67 Dress the Live and Neutral wires
and ribbon cable neatly under
the flaps on the underside of the
motor mount.