UVWO TERMINAL OUTPUT VOLTAGES
Various output voltages can be obtained using the UVWO
output terminal lugs. The voltages at the terminals are
dependent on the adjustment of the voltage regulator
(Figure 11). The voltage regulator allows the user to
increase or decrease the selected voltage.
3-Phase 240-Volt / Single-Phase 139-Volt
UVWO Terminal Output Voltages
NOTICE
ALWAYS make sure that the connections to the UVWO
terminals are secure and tight. The possibility of arcing
exists that could cause a fire.
1. Connect the load wires to the UVWO terminal lugs
as shown in Figure 10.
BLACK
RED
U
V
240V
240V
Figure 10. UVWO Terminal Lugs
(3-Phase 240-Volt / 1-Phase 139-Volt Connections)
2. Turn the voltage regulator (Figure 11) clockwise
to increase voltage output as needed. Turn
counterclockwise to decrease voltage output.
DECREASE
Figure 11. Voltage Regulator
PAGE 22 — TLG8SSK4F2 PORTABLE GENERATOR • OPERATION MANUAL — REV. #0 (04/06/23)
OUTPUT TERMINAL PANEL CONNECTIONS
BLUE
WHITE
GREEN
W
O
240V
139V
GROUND CONNECTION
139V
MUST BE USED
AT ALL TIMES
139V
INCREASE
3-Phase 208-Volt / Single-Phase 120-Volt
UVWO Terminal Output Voltages
1. Connect the load wires to the UVWO terminal lugs
as shown in Figure 12.
BLACK
RED
U
V
208V
208V
Figure 12. UVWO Terminal Lugs
(3-Phase 208-Volt / 1-Phase 120-Volt Connections)
NOTICE
To achieve 3-phase 208-volt output, the voltage
regulator (Figure 11) must be adjusted to 208 volts.
BLUE
GREEN
WHITE
O
W
208V
120V
GROUND CONNECTION
MUST BE USED
AT ALL TIMES
120V
120V