HACCP value can be configured to be reported as the value of a choice
between a few different sensor values. This can be configured under
Config > Refrigeration > Temperature Sensors > HACCP Sensor.
Available Expansion Modules
HSVD20 - Dual Valve Driver
Used for additional IO for Micro-Distributed Setups.
Application
The application will have the option to support up to three separate
zones. To maintain case temperature, the application will use discharge
air temperatures and safeties to manage cold operations.
Internal Web Server
The CoreLink case controller features a friendly user interface that can
be accessed by web browser.
This Web UI can be accessed by in store network via windows
computer or with a wireless link device that can be viewed by
technician through smart devices.
Data Logging
The case control application has internal logging for each sensor along
with critical operation data. Data is available for local download.
2-minute intervals
14-day capacity
Advanced analytics; web user interface
CSV format with 15 critical data points
Onboard data logging allows user to review performance data from the
past week. User can see Min/Max/Average data along with saving data
sets and importing data sets for view.
To learn more about CoreLink Case Controllers including instruction manuals and guides, please visit Hussmann.com.
https://www.hussmann.com/products/case-controls/case-controls/corelink-case-controller
HUSSMANN CORPORATION • U.S. & CANADA 1-800-922-1919 • BRIDGETON, MO 63044-2483 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM • PN 3053328_H
Factory Restore
The CoreLink application has a configuration file with the complete and
optimized default case settings.
Anytime a user wants to default to factory settings they can simply
access the user interface and force a factory reset.
Save / Load Feature
The CoreLink Case Controller is setup from the factory with a specific
product configuration when a customer purchases a display case.
This specific configuration is hardcoded into the controller and is
the factory default file. Also included are three user presets that a
user can save or load custom configuration settings. These settings
allow customers to make small tweaks in the field that can improve
performance or target temperatures.
Standalone Operation
Controller is configured from the factory to run as a standalone
controller. Field network integrations are done to provide additional
capabilities to the controller. In case of network failure of BAS
managing additional control functions, controller will default to its
standalone settings and regulate display case until network connection
is restored.
In case of network failure to building automation system managing
case setpoints, the controller will default to program settings in internal
memory and continue to regulate display case until network con-
nection is restored.