These self-contained merchandisers have water-cooled condensers.
Each coil section has a dedicated refrigeration system.
Providing Information About Safety Messages in Collateral Materials and Product
All the electrical connections are to be made in the electrical box,
located on top of the case at the right side.
A1
Explanation of Signal Words and Symbols
Signal words and safety symbols that are used in a product's collateral materials or on the product may
be defined in collateral materials if space is available.
A1.1
Safety Alert Symbol
The meaning of the safety alert symbol may be provided in collateral materials. The following artwork may
be used for this purpose.
A1.2
Signal Words
The meaning of the different signal words as defined by the ANSI Z535.6 and ANSI Z535.4 standards
may be explained in collateral materials. The following artwork may be used for this purpose.
2-2
— LOCK OUT / TAG OUT —
»
Merchandiser must be grounded. All wiring must be in
compliance with NEC and local codes.
»
To avoid serious injury or death from electrical shock,
always disconnect the electrical power at the main
disconnect when servicing or replacing any electrical
component. This includes, but is not limited to, such items
as doors, lights, fans, heaters, and thermostats.
A1.3
Other Highlighting Conventions
The meaning of any other highlighting conventions used to differentiate safety messages (e.g., text
manipulations, indention, etc.) may be explained in collateral materials.
HUSSMANN CORPORATION • U.S. & CANADA 1-800-922-1919 • BRIDGETON, MO 63044-2483 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM • PN 3053328_H
A1.4
Safety Symbols
The meaning of any safety symbols used on safety labels or collateral materials may be explained in
A1.1
Safety Alert Symbol
The meaning of the safety alert symbol may be provided in collateral materials. The following artwork may
be used for this purpose.
Annex A
Safety Signs and Labels
(Informative)
A1.2
Signal Words
The meaning of the different signal words as defined by the ANSI Z535.6 and ANSI Z535.4 standards
may be explained in collateral materials. The following artwork may be used for this purpose.
This is the safety alert symbol. It is used to alert you
to potential physical injury hazards. Obey all safety
messages that follow this symbol to avoid possible
injury or death.
It is the installing contractor's
responsibility to consult
local agencies for local code
requirements.
A1.3
Other Highlighting Conventions
DANGER indicates a hazardous situation which, if not
avoided, will result in death or serious injury.
The meaning of any other highlighting conventions used to differentiate safety messages (e.g., text
manipulations, indention, etc.) may be explained in collateral materials.
A1.4
Safety Symbols
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
The meaning of any safety symbols used on safety labels or collateral materials may be explained in
collateral materials.
CAUTION indicates a hazardous situation which, if not
© 2017 National Electrical Manufacturers Association
avoided, could result in minor or moderate injury.
Copyright National Electrical Manufacturers Association
Provided by IHS Markit under license with NEMA
No reproduction or networking permitted without license from IHS
NOTICE is used to address practices not related to
physical injury.
Safety instructions (or equivalent) signs indicate specific
safety-related instructions or procedures.

PLUG

Water Inlet
The optional plug cord is 8ft long and is located on the right hand rear
This is the safety alert symbol. It is used to alert you
to potential physical injury hazards. Obey all safety
of the merchandiser. Disconnect power before servicing. Merchandisers
Water Outlet
messages that follow this symbol to avoid possible
require a dedicated electrical circuit with ground. 12AWG is the
injury or death.
minimum sized acceptable wire for a 20-amp circuit.
2, 3 and 4-door cases require a dedicated 20-amp / 208V - 3 phase circuit
with a grounded wall receptacle (NEMA L21-20R).
DANGER indicates a hazardous situation which, if not
avoided, will result in death or serious injury.
NEMA L21-20R
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
5-door cases require a dedicated 30-amp / 208V - 3 phase circuit
CAUTION indicates a hazardous situation which, if not
with a grounded wall receptacle (NEMA L21-30R).
avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to
Water Line Assembly Outlet
physical injury.
NEMA L21-30R
Safety instructions (or equivalent) signs indicate specific
safety-related instructions or procedures.
RM-W & RMN-W cases require a dedicated a NEMA 5-15R
grounded wall receptacle.
NEMA 5-15R
• Always use a dedicated circuit with the amperage stated
on the unit.
• Plug into an outlet designed for the plug.
Licensee=Hussmann Corp/8160899001, User=Trevett, Jason
Not for Resale, 02/16/2021 11:49:55 MST
• Do not overload the circuit.
• Do not use long or thin extension cords. Never use
adapters.
• If in doubt, call an electrician.
2-2
Front of Case
Water Line Assembly Inlet
Water Line Assembly Outlet
Water System Bracket
Condensing Unit
Water Line Assembly Inlet
Water System Bracket
Condensing Unit
Front of Case
2-4