Using the Transmitter
With ProLink II
To view current totals for the totalizers and inventories with ProLink II:
1. Click
ProLink
2. Select
Process Variables
With a DeviceNet tool
To view current totals for the totalizers and inventories with a DeviceNet tool, see Section 7.3.3.
7.7.2

Controlling totalizers and inventories

Specific starting, stopping, and resetting functionality depends on the tool you are using.
With the display
If the required value is shown on the display, you can use the display to start and stop all totalizers
and inventories simultaneously, or to reset individual totalizers. See the flowchart in Figure 7-3. You
cannot reset any inventories with the display.
Figure 7-3
Controlling totalizers and inventories with the display
Process variable
display
Scroll
(1)
Mass total
Scroll
Select
EXIT
Scroll
(1) Displayed only if configured as a display variable.
(2) The petroleum measurement application or enhanced density application must be enabled.
(3) The Event Setpoint screens can be used to define or change Setpoint A for Event 1 or Event 2 only. These screens are displayed
only for specific types of events. To change the setpoint for an event defined on mass total, you must enter the totalizer
management menu from the mass total screen. To change the setpoint for an event defined on volume total, you must enter the
totalizer management menu from the volume total screen. See Section 8.6.3 for more information.
(4) The display must be configured to allow stopping and starting. See Section 8.9.3.
(5) All totalizers and inventories will be stopped and started together, including API and enhanced density totalizers and inventories.
(6) The display must be configured to allow totalizer resetting. See Section 8.9.3.
(7) Only the totalizer currently shown on the display will be reset. No other totalizers will be reset, and no inventories will be reset.
Be sure that the totalizer you want to reset is displayed before performing this reset.
Configuration and Use Manual
.
,
API Process Variables,
(1)
Volume total
Scroll
(3)
E1--SP
Scroll
(3)
E2--SP
STOP/START YES?
Select
or
ED Process Variables.
API total
(1)(2)
(1)(2)
ED total
(4)(5)
STOP/START
Scroll
Select
Yes
No
Scroll
(6)(7)
RESET
Scroll
Select
RESET YES?
Yes
No
Select
Scroll
49