Emerson Micro Motion 2400S Configuration And Use Manual page 156

Transmitter for devicenet
Hide thumbs Also See for Micro Motion 2400S:
Table of Contents

Advertisement

Device Profile
Table C-6
Calibration Object (0x65) – Instance 1 continued
Attrib
ID
Name
13
D2
14
FD
15
D3
16
D4
17
Density
temperature
coefficient
18
FTG
19
FFQ
20
DTG
21
DFQ1
22
DFQ2
23
Temperature
offset
24
Temperature
slope
25
Enable
temperature
comp
26
External
temperature
27
Enable pressure
compensation
28
External
pressure
29
Pressure units
30
Pressure factor
flow
31
Pressure factor
density
32
Flow cal
pressure
148
Data type
Service
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
REAL
Set
BOOL
Set
REAL
Set
BOOL
Set
REAL
Set
UINT
Set
REAL
Set
REAL
Set
REAL
Set
Mem
Description
NV
The line-condition density
of D2 calibration service
NV
The line-condition density
of FD calibration service
NV
The line-condition density
of D3 calibration service
NV
The line-condition density
of D4 calibration service
NV
The DT or TC calibration
factor
NV
T-Series: flow TG
coefficient
NV
T-Series: flow FQ
coefficient
NV
T-Series: density TG
coefficient
NV
T-Series: density FQ
coefficient #1
NV
T-Series: density FQ
coefficient #2
NV
Temperature offset
NV
Temperature slope
NV
Enable or disable
temperature
compensation
V
The external temperature
value from output
assembly instance 51 or
52
NV
Enable or disable
pressure compensation
V
The external pressure
value from output
assembly instance 50 or
52
NV
Units used by external
pressure input
NV
The pressure correction
factor for flow
NV
The pressure correction
factor for density
NV
The flow calibration
pressure
®
Micro Motion
Model 2400S Transmitters for DeviceNet
Comments
3
Unit = g/cm
3
Unit = g/cm
3
Unit = g/cm
3
Unit = g/cm
• 0 = Disabled
• 1 = Enabled
• 0 = Disabled
• 1 = Enabled
See Table 6-7 for unit
codes.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micro motion 2400s dn