Click the Add Record button
3. Enter all information required about each Switch Node
S X 6 5 0 S w i t c h N o d e - D e f i n i t i o n
F i e l d D a t a
ID Unique record ID assigned by Admin Console as a node is added, in order to identify one node to the
system. 1 to 1,098.
Admin Console automatically generates this number in consecutive order. Upon adding nodes, the
system will automatically assign the next available number.
Since logical and local numbers are not necessarily unique or consecutive, and the permission grids are
displayed as consecutive, unique numbers; Admin Console generates these ID numbers.
I/F Numeric Ethernet interface number identifying a port on a CPU where the matrix frame will connect. 0 to
15, though generally 0, 1, or 2.
IPA Unique Internet Protocol address assigned by the system administrator. Dotted decimal, 15 characters
(including dots). Example: 128.010.050.125
Name A name for the switch node. Alphanumeric, 16 characters.
Location A name for the matrix frame location. Alphanumeric, 16 characters.
BRIDGE Check
If BRIDGE (system interface function) is checked, then select range of Output Ports.
This range will be unique to the entire system for the bridge function; port range is 1 - 64.
CONTROL Check
If CONTROL (controlling function) is checked, you would need to select a range of numbers in Input
Ports.
This range will be unique to the entire node for the control function based on the number of input cards
installed within the sub-node; input ports are 1 – 1024.
OSD Check
If OSD (character overlay function) is checked, you would need to select a range of numbers in Output
Ports.
This range will be unique to the entire node for the OSD function based on the number of output cards
installed within the sub-node.
SWITCH Check
If SWITCH (matrix switching function) is checked, then select a range of numbers in Input Ports and
Output Ports.
This range will be unique to the entire system function, based on the number of input and output cards
installed within the sub-node; input port range is 1 – 1024; output port range is 1 - 64.
ALARM Check
If ALARM (alarm I/O function) is checked, then select a range of numbers in I/O Ports.
This range will be unique to the entire node for the alarm I/O function, based on the number of output
cards installed within the sub-node.
Node Address Set the Node Address to the [MODE] switches of the BRIDGE sub-node. 0 0-0-0 to 1-1-0-1.
EA Numeric address for an Ethernet controller. This field is only required if MODE switch
Address is not chosen. Dotted hexadecimal Example: 23.56.82.13.60.82 (Also known as MAC
address.) Use all zeroes if not using DHCP.
4. Click the green check mark to save
Configuration
if this SX650 switch sub-node will be used as a node bridge.
if this SX650 sub-node will use camera control function.
if this SX650 sub-node will provide OSD function.
if this SX650 sub-node will provide switching function.
if this SX650 sub-node will provide alarm control.