Panasonic WJ-MPU955A User Manual page 105

Admin console
Hide thumbs Also See for WJ-MPU955A:
Table of Contents

Advertisement

2. Add, edit, delete, or replicate operators, as needed, using the four icons at the
bottom of this window.
The maximum number of operators that can be defined for the system is 512.
O P E R A T O R S
F i e l d D a t a
Operator ID Operator logon identification. This ID is different from all other component IDs. An
administrator assigns it. It is not assigned automatically as is the case with other components.
This number does not need to be sequential. This will be used as the log-on ID assigned to
each operator. 1 to 65,534.
Password Operator password. After the operator has entered the logon ID to a system controller, this
numeric password must be entered to complete the logon process. 1 to 99,999.
Name Operator's name, in any format. Alphanumeric, 20 characters.
Class Choose the class this operator is to be added to from the classes available on the drop-down
menu.
Priority Sets precedence among operators. Alarm priority has precedence over the operator priority.
Operator priority has precedence over the system controller priority. The operator with the
lower number priority takes over the part of the system being addressed. If more than one user
with the same priority is operating at the same time, access is given according to the lowest
controller priority number. If both priorities are the same, access is given and held for the
latest call to a function, in other words, on a last-come first-served basis. 0 to 65,534.
Timeout Number of seconds that must elapse after the user stops entering keystrokes before the system
logs the operator off of this controller. Up to 11:59:59 (hr:min:sec).
The operator timeout works in conjunction with the controller timeout. The system will use
the lowest timeout value of the two.
Entering a "0" into this field will cause the timer to never expire regardless of the controller
timeout value.
Class privileges granted for the selected class also appear on Definition tab of this
window, but cannot be changed. This is shown for the administrator's reference only.
Changes to class privileges must be done through the Operator Classes window. See
page 96 for details.
Configuration
101

Advertisement

Table of Contents
loading

Table of Contents