MERLIN STEALTH MASTER
Electric Fence Energizer
INSTALLERS MANUAL
Revision 1.0
21/08/2006

Advertisement

loading

Summary of Contents for Nemtek MERLIN STEALTH MASTER

  • Page 1 GROUP OF COMPANIES MERLIN STEALTH MASTER Electric Fence Energizer INSTALLERS MANUAL Revision 1.0 21/08/2006...
  • Page 2: Table Of Contents

    MERLIN STEALTH: INSTALLERS MANUAL Table of Contents INTRODUCTION…..…………………………………………………………………… CONSIDERATIONS IN A NETWORKED ENERGIZER………………………………… 5 DEFAULTING THE MASTER AND SLAVE ENERGIZERS…………………………. CONVERTER CARD SETTINGS…………………………….……………..…………….. CONNECTING THE NETWORK…………………………….……………..…………….. PROGRAMMING THE NETWORK………………………….……………..…………….. PROGRAMMING INDIVIUAL ENERGIZERS…………………………..…………….. NETWORKING EXAMPLES…………………………………………..……..…………….. 11-13...
  • Page 3: Introduction

    MERLIN STEALTH MASTER Introduction INTRODUCTION This manual must read and used in conjunction with the Merlin Stealth Installer manual. The Merlin Stealth Energizer™ range of energizers are configurable to be part of a networked security system. This enables control and monitoring of multiple energizers from one central location or from any location in the world with internet access.
  • Page 4 Permits energizers to become part of a local area network or to be accessed remotely. A range of communication protocols have been incorporated to provide flexibility / security and connectivity. Visit www.nemtek.com for more information and contact details.
  • Page 5: Considerations In A Networked Energizer

    32 devices before some buffering is required. Unlike RS485, fiber-optics is always configured point to point with only two devices being connected. The standard Nemtek fiber-optic components have a range of 3km. (It is possible to extend this to 20km.) 3.
  • Page 6: Defaulting The Master And Slave Energizers

    MERLIN STEALTH MASTER Defaulting the Energizers DEFAULTING THE ENERGIZERS Before the energizers can be configured into a network all energizers have to be put into their factory default condition. The Master energizer can only be defaulted with a 20 zone Keypad and the Slave energizer can be defaulted only with a 1 or 2 zone Keypad.
  • Page 7: Converter Card Settings

    MERLIN STEALTH MASTER Converter card settings CONVERTER CARD SETTINGS There are two converter cards available for the communication interface between the energizers. 1) The Stealth RS 485 converter card. The card converts RS485 to RS 232. 2) The Stealth Fibre Optic converter card.
  • Page 8: Connecting The Network

    MERLIN STEALTH MASTER Converter card settings To decide if Jumper 1 should be inserted ask the question if the converter does not repeat the signal will a message from the Master reach the Slaves and will a message from the Slaves reach the Master.
  • Page 9: Programming The Network

    MERLIN STEALTH MASTER Programming the Network PROGRAMMING THE NETWORK 1) Default all the energizers as described under defaulting the energizer. 2) Enter the Installer Pin on the Master energizer (see Merlin Stealth Installer manual). 3) If the converter card connected to the Master RS232 port connects to the energizers...
  • Page 10: Programming Indiviual Energizers

    MERLIN STEALTH MASTER Programming the energizers PROGRAMMING THE INDIVIDUAL ENERGIZERS After the network is programmed the Master and Slave units can now individual be programmed to suit the requirements i.e. gate delay times, siren on times, fence alarm voltage etc.
  • Page 11 MERLIN STEALTH MASTER Networking examples RS 232 NETWORKED Units : One Master and One Slave Zones : Maximum 4 Zones Cable : Twisted pair and Earth-Screen (120 Ohm) Cable Length : Maximum 6 Meters Housing : In same room or building...
  • Page 12: Networking Examples

    MERLIN STEALTH MASTER Networking examples RS 484 NETWORKED WITH EXTENDED DISTANCE Units : One Master and Maximum 9 Slaves RS485-RS232 Card : JP1 Installed only on first and last Zones : Maximum 20 Zones unit and on both units in the...
  • Page 13 MERLIN STEALTH MASTER Networking examples FIBRE OPTIC STAR CONNECTED Units : One Master and Maximum 9 Slaves RS485-RS232 Card : JP 1 Installed Zones : Maximum 20 Zones RS485-FIBRE Card : JP 3 in position 1&2 on all units Cable : Twisted pair and Earth-Screen (120 Ohm)