GROUP OF COMPANIES
MERLIN STEALTH M113S
Electric Fence Energizer
M113S
Users Manual
Revision 1.0
Date: 29 January 2007
PDF created with pdfFactory trial version
www.pdffactory.com

Advertisement

Table of Contents
loading

Summary of Contents for Nemtek MERLIN STEALTH M113S

  • Page 1 GROUP OF COMPANIES – MERLIN STEALTH M113S Electric Fence Energizer M113S Users Manual Revision 1.0 Date: 29 January 2007 PDF created with pdfFactory trial version www.pdffactory.com...
  • Page 2: Table Of Contents

    MERLIN STEALTH M113S Table of Contents FOREWORD…..………………………………………………………………………….. GUARANTEE…..………………………………………………………………………….. INTRODUCTION…..…………………………………………………………………… OPERATION WITHOUT A KEYPAD….…………………………………………… OPERATION WITH A KEYPAD…………………………………………………….. USING YOUR KEYPAD KEYPAD…………………………………………………….. 6-10 FENCE INDICATOR LIGHTS………………………………………………………… WHAT THE ENERGIZER LIGHTS INDICATE…………………………………… WHAT THE KEYPAD LIGHTS INDICATE………………………………………… DOCUMENT REVISION HISTORY…………………………………………………. No user serviceable parts inside the energizer.
  • Page 3: Foreword

    Foreword MERLIN STEALTH M113S FOREWORD The Merlin Range of energizers has evolved over the past fifteen years. The energizers are designed to comply with the latest international specifications. In order to offer some product flexibility the embedded software in the energizers may change.
  • Page 4: Guarantee

    IO Tech Manufacturing (Pty) Ltd does not guarantee that the operation of the product will be uninterrupted and totally error free. Faulty units must be returned to Nemtek, Units 4 & 5, 64 Vervoer Street, Kya Sand, Randburg, Gauteng, South Africa OR Nemtek Security Warehouse, Unit 4, Meadowdale Park, Cnr.
  • Page 5: Introduction

    The energizer should ideally be operated by means of a remote keypad. This enables the user to have access to many energizer features and offers the greatest security. It can, however, be operated by means of a Nemtek tab or a remote on/off switch.
  • Page 6: Using Your Keypad Keypad

    M113S MERLIN STEALTH Using your KEYPAD security reasons they have no default codes and must be assigned by the master user. A reset user may only reset the alarms but not change the On/Off state of the energizer. User #4,#5,#6. For security reasons they have no default codes and must be assigned by the master user.
  • Page 7 M113S MERLIN STEALTH Using your KEYPAD indicator notifies the user that the fault no longer exists. In the latter case simply turning the energizer on again will clear the memory condition. If the flashing alarm condition cannot be resolved, the alarm will be activated irrespective of the number of times the unit is turned On or Off.
  • Page 8 M113S MERLIN STEALTH Using your KEYPAD MAKE THE GATE ALARM IMMEDIATE(Gate 1) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 7, followed by the digit 1, then press the # key. The GATE ALARM light will start flashing, with a cadence of one flash every 5 seconds, to confirm the gate alarm is immediate.
  • Page 9 M113S MERLIN STEALTH Using your KEYPAD BYPASS THE GATE ALARM (Gate 2) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 2, then press the # key. To cancel the bypass, repeat the same sequence of keys. TURN THE GATE CHIME ON (Gate1) Enter your PIN (master only) and the * key, enter the digit 2, enter the digit 8, enter the digit 1, then press the # key.
  • Page 10 M113S MERLIN STEALTH Using your KEYPAD MANUAL BATTERY TEST Enter your PIN (master only) and press the * key, enter the digit 6, then press the # key. The keypad will beep four times indicating the battery test has started. This test disables the mains input for 20 minutes and monitors the battery voltage.
  • Page 11: Fence Indicator Lights

    M113S MERLIN STEALTH Fence Indicator Lights MERLIN S What the Energizer lights indicate FENCE INDICATOR LIGHTS The M113S energizer monitors the fence with every pulse. A finite amount of energy is used to excite the fence. Depending on the current magnitude of a fence pulse a second pulse may be used to excite the fence and effectively double the output energy.
  • Page 12: What The Energizer Lights Indicate

    M113S MERLIN STEALTH What the Energizer lights indicate WHAT THE ENERGIZER LIGHTS INDICATE Power Fence Fence Fence Gate Light High Power Service Condition: Remarks Light Light Good Check Alarm (1 or 2) Light Light Fence on, SLOW FENCE GOOD working FLASH properly Fence off,...
  • Page 13: What The Keypad Lights Indicate

    M113S MERLIN STEALTH What the Keypad lights indicate WHAT THE KEYPAD LIGHTS INDICATE Gate Power Good Fence Service Condition: Light(1 Remarks Light Light Light Light Light or 2) Fence on, working FENCE GOOD properly Fence off, working FENCE OFF properly SLOW Fence turned off with FENCE OFF...
  • Page 14: Document Revision History

    M113S MERLIN STEALTH Document Revision History DOCUMENT REVISION HISTORY Revision 1.0 29 January 2007 End of document PDF created with pdfFactory trial version www.pdffactory.com...