Nemtek MERLIN STEALTH MASTER User Manual
Nemtek MERLIN STEALTH MASTER User Manual

Nemtek MERLIN STEALTH MASTER User Manual

Electric fence energizer
Hide thumbs Also See for MERLIN STEALTH MASTER:

Advertisement

GROUP OF COMPANIES
MERLIN STEALTH MASTER
Electric Fence Energizer
Users Manual
Revision 1.1
20/7/2007

Advertisement

loading

Summary of Contents for Nemtek MERLIN STEALTH MASTER

  • Page 1 GROUP OF COMPANIES – MERLIN STEALTH MASTER Electric Fence Energizer Users Manual Revision 1.1 20/7/2007...
  • Page 2: Table Of Contents

    MERLIN STEALTH MASTER Table of Contents FOREWORD…..………………………………………………………………………….. GUARANTEE…..………………………………………………………………………….. INTRODUCTION…..…………………………………………………………………… USING YOUR MASTER KEYPAD……………………………………………….…. MASTER KEYPAD DISPLAY………………………………………………………….. KEYPADS ON INDIVIDUAL ENERGIZERS………………………………………. ALARM EVENT…………………………………………………………………………. 9-10...
  • Page 3: Foreword

    (RS232) and energy output and electromagnetic interference levels that comply with the very latest IEC specifications. In August 2006 the Merlin Stealth Master was added to the range. The Master unit can control and communicate with a maximum of 9 Slave units (M25S or M28S) which will than form together a 20 zone network system.
  • Page 4: Guarantee

    IO Tech Manufacturing (Pty) Ltd does not guarantee that the operation of the product will be uninterrupted and totally error free. Faulty units must be returned to Nemtek, Units 4 & 5, 64 Vervoer Street, Kya Sand, Randburg, Gauteng, South Africa OR Nemtek Security Warehouse, Unit 4, Meadowdale Park, Cnr.
  • Page 5: Introduction

    Introduction MERLIN STEALTH MASTER INTRODUCTION 1.0 Introduction The Merlin Stealth Energizer M25S Master or M28S Master enables up to ten energizers to be networked. The system user can send through the Master energizer global or energizer specific commands to turn energizers On/Off and change between High- Voltage and Low-Voltage modes.
  • Page 6: Using Your Master Keypad

    MASTER MERLIN STEALTH Using your MASTER KEYPAD USING YOUR MASTER KEYPAD Global Commands Global Commands are commands from the Master keypad which the Master and the Slave Energizer must obey simultaneously. All energizers in the network to obey the commands. The status quo of the individual energizers is assumed to be that of the master when issuing a global command Example: If a four energizer system with one individual slave in the Off...
  • Page 7 MASTER MERLIN STEALTH Using your MASTER KEYPAD SPECIFIC COMMANDS Each of the energizers can be instructed to obey specific commands. Without having to go and physically look at an individual energizer it is easier to follow the following procedure. If only one energizer is required to be in the OFF state it is far easier to issue a global command and ensure all energizers are ON by verifying that the GOOD indicator is permanently lit.
  • Page 8: Master Keypad Display

    MERLIN STEALTH MASTER KEYPAD DISPLAY MASTER KEYPAD DISPLAY SUMMARY Indicator Flashing At least one energizer on. All energizers off Not all energizers in HV All energizers are in HV irrespective of voltage mode mode setting. All energizers on. No Not all energizers on. No...
  • Page 9: Alarm Event

    MERLIN STEALTH MASTER ALARM EVENT WHAT TO DO IN THE EVENT OF AN ALARM. A properly installed electric fence should not cause false alarms and any alarm condition should be investigated. An alarm condition must be cleared on the Master Keypad. This can be done by using a specific Energizer On/Off command for the energizer with the alarm condition or a global On/Off command.
  • Page 10 GLOBAL COMMAND: RESET ALL ENERGIZERS (without turning any of the energizers off and without clearing the individual energizer memory conditions) Master PIN followed by *77# The individual energizer must first be turned Off and On again to clear its own specific alarm memory condition prior to issuing this command.