3. Operation panel
Parts
Num
Item
ber
P101 Thread release start angle
P102 Thread release end angle
P103 Yarn release strength
P104
~
Invalid
P106
P107 Sewing speed at sewing start
P108 Invalid
P109 Pre-dial delay time?
P110 Trimming back time (ms)
P111 -
P112 -
P113 -
P114 -
P115 -
P116 -
P117 -
P118 -
Overcurrent protection
P119
detection of solenoid
P120
Invalid
P122
P123 Maximum stitch limit
Restoring the Factory
P124
Default Settings
P125
Invalid
P128
Home position correction of
P129
the reversing motor
P130 Invalid
46
Initial
Range
value
1-359
30
1-359
180
1-8
5
100-2000
500
5-990
5
60-990
65
0-1
0
0-990
100
0-990
90
0-990
30
0-100
80
0-5000
1000
0-100
80
0-1
1
0-1
0
0-7
5
0000-9999
0000
-500 ~ 500
0
S-7180A
Description
Thread loosening start angle (The lower position is
calculated as 0°)
Thread loosening end angle (the position below is
calculated at 0° and must be greater than the value of P101
parameter)
Yarn release strength
Sewing speed at sewing start
Time from finding the upper position to entering the dial
operation
Check that the thread trimmer has returned to the original
position.
Do not change.
Do not change.
Do not change.
Do not change.
Do not change.
Do not change.
Do not change.
Do not change.
0:OFF
1:You do.
The upper limit of P131, P132, etc., is limited.
Enter the version number of the panel and press the key to
initialize all data based on the setting of P70.
Provided, however, that the following shall be excluded.
P17-
N04、P18、P19、P25、P26、P32、P33、P58、P59、
P70、P74、P75、P92、P129、P144、P145、P177~P2
00、P235~P242
Home position correction of the reversing motor

Hide quick links: