Required clearance

The following clearance is required around the Transceiver Unit:
• At least 14 mm above the Transceiver Unit for the mounting rail
• At least 80 mm below the Transceiver Unit for the strain relief elements
The following figure shows an example with a mounting rail attached to the rear of the
Transceiver Unit. The device depth of Transceiver Unit with mounting rail is 35.2 mm.
y1 14 mm
y2 80 mm
3.1.4.3

Fastening the mounting rail

Requirements
To attach the mounting rail to the Transceiver Unit you need:
• The supplied mounting rail
• The supplied cross-tip cylinder head screw
• A torque screwdriver with cross-tip insert
IFP V2, IFP V2 PRO, IFP V2 ETH
Operating Instructions, 03/2023, A5E46641410-AE
Installing and connecting the device
3.1 Preparing for installation
41