6.1.2 Micro-Switch Introduce:
YKKE12BXTMCM-RX,YKJE12BXTMCM-RX, YKKE18BXTMCM-RX,YKJE18BXTMCM-RX,
A. Micro-switch SW1 is for selection of indoor fan stop temperature (TEL0) when it is in anti-cold wind
action in heating mode.
Range: 24
o
C, 15
o
C, 8
B. Micro-switch SW2 is for selection of indoor FAN ACTION if room temperature reaches the setponit
and the compressor stops.
Range: OFF (in 127s), Keep running.
C. Micro-switch SW3 is for selection of auto-restart function.
o
C, according to EEROM setting (reserved for special customizing).
T 2
T E L 0 + 1 6
T E L 0 + 1 4
T E L 0 + 1 2
T E L 0 + 1 0
T E L 0 + 8
T E L 0 + 6
S e tt in g fa n s p e e d
T E L 0 + 1 2
H
T E L 0 + 1 0
M +
T E L 0 + 8
M
T E L 0 + 6
L
T E L 0 + 4
S u p e r s lo w
T E L 0
F a n o ff