Replacing the lamp unit

Replacing
1. Turn off the MAIN POWER switch according to the procedure
"Switching the projector on/off" on page 19, and then disconnect the
power cord plug from the wall outlet and check that the area around
the lamp unit has cooled down.
2. Use a Phillips screwdriver to turn the lamp unit cover fixing screws at
the bottom of the projector, and then remove the lamp unit cover.
3. Use a Phillips screw driver to loosen the two lamp unit fixing screws
until the screws turn freely. Then hold the handle of the lamp unit and
gently pull it out from the projector.
4. Insert the new lamp unit while making sure that the direction of
insertion is correct, and then use a Phillips screwdriver to securely
tighten the lamp unit fixing screw.
5. Install the lamp unit cover, and then use a Phillips screwdriver to
securely tighten the lamp unit cover fixing screws.
NOTE:
Be sure to install the lamp unit and the lamp unit cover securely. If they
are not securely installed, it may cause the protection circuit to operate so
that the power cannot be turned on.
Grip the handle when you remove the lamp unit. Some parts of the lamp
unit are sharpened and may cause injury.
Resetting the LAMP RUNTIME
If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the
projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure
should thus be completed within 10 minutes.
1. Insert the power cord plug into the wall outlet and then
press the MAIN POWER switch.
2. Press the POWER button so that a picture is projected onto
the screen.
3. Press the MENU button to display the menu screen, and
then press the F or G button to select the OPTION menu.
4. Press the ENTER button, and then press the F or G button
to select LAMP RUNTIME.
5. Press and hold the ENTER button for approximately
3 seconds. The confirmation screen, "LAMP RUNTIME
RESET." is displayed and select OK.
6. Turn off the power.
This will reset the cumulative usage time for the lamp
unit to zero.
Care and Replacement
Lamp unit cover fixing screws
Lamp unit cover
Lamp unit fixing screws
Press
here
INPUT GUIDE
OSD DESIGN
OSD POSITION
BACK COLOUR
STARTUP LOGO
AUTO SEARCH
HDMI SIGNAL LEVEL
INSTALLATION
SLEEP
ALTITUDE
LAMP POWER
LAMP RUNTIME
TEST PATTERN
E
Press
here
Handle
DETAILED
TYPE1
CENTRE
BLUE
ON
ON
NORMAL
FRONT/DESK
OFF
LOW
NORMAL
1820H
- 39
NGLISH

Hide quick links: