Cleaning and replacing the air filter
If the air filter becomes clogged with dust, the internal temperature of the
projector wilt rise, the TEMP indicator will flash and the projector power will
turn off. The air filter should be cleaned after every 100 hours of use.
_._Turn off the MAIN POWER
switch and disconnect the
power cord plug from the wall
outlet,
Turn off the MAIN POWER switch
according to the procedure given
in 'q'urning off the power" on
page 24 before disconnecting the
piug from the wall outlet.
@_ Gently turn the projector
upside down.
L3_ Remove the air filter.
Put your fingernails under the air
filter and pull the air filter out of
the projector.
Air filter
_4_ Clean the air filter.
Soak the air filter in water and
wash out dirt by hand.
_5_Dry the air filter and installitto
the projecter.
46-ENGLISH
Replacing the lamp unit
NOTE:
m If you need the lamp replacement, piease purchase the lamp unit from
our customer service.
Lamp unit product no.: ET-LAE500
CAUTION:
m Do not use any lamp unit other than the one with the product number
indicated above.
Warning
When replacing the lamp, allow it
to cool for at least one hour
before handling it.
• The lamp cover gets very hot,
and contact with it can cause
burns.
Notes
on
replacing
the lamp
unit
• The light generating lamp is
made of glass, so dropping it or
allowing it to hit hard objects may
cause it to burst. Be careful when
handling the lamp.
• Dispose of the removed old lamp
with the same care that would be
taken with a fluorescent light.
• A Phillips screwdriver is
necessary for removing the lamp
unit.
Lamp unit replacement
period
The lamp is a consumable product.
Even when the full life of the bulb
has not been exhausted, the
brightness of the light wilt gradually
decline. Therefore periodic
repiacement of the lamp is
necessary.
The intended lamp replacement
interval is 2 0O0 hours, but it is
possible that the lamp may need to
be replaced earlier due to variables
such as a particular lamp's
characteristics,
usage conditions
and the installation environment.
Early preparation for lamp
replacement is encouraged.
The lamp wilt automatically shut off
when 2 000 hours of use have been
reached because of a much greater
chance of it exploding after this
time.
ENGLISH-47