Technical Data - Viking FREEDOM VK480 Technical Data Manual

Residential concealed horizontal sidewall sprinkler

Advertisement

Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com.
4. INSTALLATION
Refer to appropriate NFPA or EN Installation Standards.
5. OPERATION
During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches.
Continued heating of the exposed sprinkler causes the fusible element to disengage, releasing the sealing assembly. Water flowing
through the sprinkler orifice strikes the flow shaper, forming a uniform spray pattern over a specific area of coverage determined
by the water supply pressure at the sprinkler to extinguish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
Viking Freedom® Residential Concealed Horizontal Sidewall Sprinkler VK480 is available through a network of domestic and
international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
Size
Sprinkler
Base Part
NPT
Number
1
Inch
16116
1/2
Accessories
Sprinkler Wrenches and tools:
A. Heavy Duty Part Number: 16208W/R
B. Head Cabinet Wrench Part Number: 16267
C. Optional Concealed Cover Plate Installer Tool Part Number: 14412 (available since 2007)
D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007)
Sprinkler Cabinet:
Holds up to 6 sprinklers: Part number 01731A (available since 1971).
Footnotes
Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule.
1.
Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having
2.
Jurisdiction. Refer to specific installation standards.
Requires a 13 mm (½") ratchet (not available from Viking).
3.
Also optional for removal of the protective cap. Ideal for sprinkler cabinets.
4.
cULusEU Listed as corrosion resistant.
5.
The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and
6.
do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed
environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville
spring is exposed.
The sprinkler temperature rating is stamped on the deflector.
7.
LPCB Listed - Brass Only.
8.
Form No. F_121609
Rev 01

TECHNICAL DATA

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
TABLE 1: SPRINKLER ORDERING INFORMATION
Instructions: Using the sprinkler base part number,
(1) add the suffix for the desired Finish
(2) add the suffix for the desired Temperature Rating.
(3) Select a cover plate (See Table 2)
1: Finishes
Description
Suffix
Brass
8
ENT
5,6
Corrosion Resistant
Sprinkler Finish: ENT
(available since 2006)
3
(available since 2006)
3,4
September 7, 2022
Nominal Rating
A
165 °F (74 °C)
JN
205 °F (96 °C)
165 °F (74 °C) Temperature Rated Sprinkler with an ENT finish.
FREEDOM
RESIDENTIAL
®
CONCEALED HORIZONTAL
SIDEWALL SPRINKLER VK480
(K4.0)
2: Temperature Ratings
7
Max. Ambient Ceiling
Temperature
100 °F (38 °C)
150 °F (65 °C)
Example: 16116JNC =
Page 2 of 9