Technical Data; Operation - Viking MicrofastHP VK346 Technical Data Manual

Quick response fusible element hsw high pressure sprinkler k2.8

Advertisement

Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com.

5. OPERATION

During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spring assemblies to open
the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extin-
guish or control the fire.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
7. AVAILABILITY
Viking Quick Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See
The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES
Sprinkler Temperature
Classification
Ordinary
Intermediate
High
Sprinkler Finishes: Brass, Chrome, White Polyester
Corrosion Resistant Sprinkler Coatings: ENT
Decorative sprinklers may not be color coded. The temperature rating is stamped on the deflector.
1
Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
2
Refer to specific installation standards.
The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These
3
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com-
patible with or suitable for the proposed environment. Note that the spring is exposed on sprinklers with ENT coatings. For ENT coated automatic
sprinklers, the waterway is coated.
cULus Listed as corrosion resistant.
4
For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with
5
Polyester coatings.
Form No. F_071614
21.03.05

TECHNICAL DATA

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Sprinkler Nominal
Temperature Rating
165 °F (74 °C)
205 °F (96 °C)
280 °F (138 °C)
3,4
Figure 1: Sprinkler Wrenches
Rev 21.1
Maximum Ambient
Ceiling Temperature
1
, Black Polyester
, and ENT
5
5
Footnotes
A
MicrofastHP
RESPONSE FUSIBLE
ELEMENT HSW HIGH PRES-
SURE SPRINKLER VK346 (K2.8)
2
100 °F (38 °C)
150 °F (65 °C)
225 °F (107 °C)
3,4
B
Page 2 of 5
QUICK
®
Frame Paint
Color
None
White
Blue