Gas Furnace; Shipping And Packing List; Safety Information - Lennox A96DFMV Installation Instructions Manual

Warm air gas furnace downflow air discharge
Table of Contents

Advertisement

A96DFMV Gas Furnace
The A96DFMV Category IV gas furnace is equipped with a
variable capacity, varable speed integrated control. Each
A96DFMV is shipped ready for installation in the Downflow
air discharge position.
The furnace is equipped for installation in natural gas
applications only. A changeover kit must be ordered for LP/
propane applications.
The A96DFMV must be installed only as a Direct Vent
gas central furnace
NOTE: In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors. See
Figure 2 for applications including roof termination.
DIRECT VENT INSTALLATION

Shipping and Packing List

1 - Assembled A96DFMV unit.
1 - Bag assembly containing the following:
3 - Wire nuts
1 - Snap bushing
1 - Snap Plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap cap clamp
1 - 3/8" NPT to 1/2" PVC fitting
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
Please refer to specification sheets for available accessories.
Page 4 of 52
Figure 2

Safety Information

DANGER OF EXPLOSION!
There are circumstances in which odorant used with LP/
Propane gas can lose its scent. In case of a leak, LP/
Propane gas will settle close to the floor and may be difficult
to smell. An LP/Propane leak detector should be installed
in all LP applications.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life. Installation and service must be performed
by a licensed professional installer (or equivalent), service
agency or the gas supplier.
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
Use only the type of gas approved for use with this furnace.
Refer to unit nameplate.
Building Codes
In the USA, installation of gas furnaces must conform with
local building codes. In the absence of local codes, units
must be installed according to the current National Fuel Gas
Code (ANSI Z223.1/NFPA 54). The National Fuel Gas Code
is available from the American National Standards
Institute, Inc., 11 West 42nd Street, New York, NY 10036.
Installed Locations
In Canada, installation must conform with current National
Standard of Canada CSA-B149 Natural Gas and Propane
Installation Codes, local plumbing or waste water codes and
other applicable local codes.
The furnace is designed for installation clearances to
combustible material as listed on the unit nameplate and in
the Tables 1 and 2. Accessibility and service clearances
must take precedence over fire protection clearances.
NOTE: For installation on combustible floors, the furnace
shall not be installed directly on carpeting, tile, or other
combustible material other than wood flooring.
Issue 1034