TECHNICAL DATASHEET
PMT Panel Mount Power Supply
5 V 50 W 1 Phase / PMT-5V50W1A□
Overload & Overcurrent Protections
The power supply's Overload (OLP) and Overcurrent (OCP)
Protections will be activated when output current exceeds 105% of
I
(Max load). In such occurrence, the V
O
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into "Hiccup
mode" (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and I
the specifications.
It is not recommended to prolong the duration of Io when it is
<105% but >100%, since it may cause damage to the PSU.
Short Circuit Protection
The power supply's output OLP/OCP function also provides
protection against short circuits. When a short circuit is applied, the
output current will operate in "Hiccup mode", as shown in the
illustration in the OLP/OCP section on this page. The power supply
will return to normal operation after the short circuit is removed.
Others
Attention
Delta provides all information in the datasheets on an "AS IS" basis and does not offer any kind of warranty through the information for
using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail
(please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or
action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using
the product before placing an order with Delta.
Delta reserves the right to make changes to the information described in the datasheets without notice.
Manufacturer and Authorized Representatives Information
Manufacturer
Thailand
Delta Electronics (Thailand) PCL.
909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand
Authorized Representatives
The Netherlands
Delta Greentech (Netherlands) B.V.
Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
12
www.DeltaPSU.com (February 2022, Rev. 08)
Overvoltage Protection
The power supply's overvoltage circuit will be activated when its
internal feedback circuit fails. The output voltage shall not exceed
will start to droop and
its specifications defined on Page 3 under "Protections".
O
is back within
O
Over Temperature Protection
As mentioned above, the power supply also has Over Temperature
Protection (OTP). In the event of a higher operating temperature at
100% load, the power supply will run into OTP when the operating
temperature is beyond what is recommended in the de-rating
graph. When activated, the output voltage will go into bouncing
mode until the temperature drops to its normal operating
temperature as recommended in the de-rating graph.
Taiwan
Delta Electronics, Inc.
3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County
32063, Taiwan
United Kingdom
Delta Electronics Europe Limited
1 Redwood Court, Peel Park Campus,
East Kilbride, Glasgow, G74 5PF, United Kingdom

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmt-5v50w1a seriesPmt-5v50w1aaPmt-5v50w1ag

Table of Contents