Screw Mounting - Honeywell Versatilis Signal Scout Installation And User Manual

Table of Contents

Advertisement

Chapter 5 - Setting up the Honeywell Versatilis Signal Scout
4. Stick the Signal Scout fitted with an adhesive adapter onto the
target structure (like beams, structure, frames, pipes, and etc).
Apply an adequate pressure on the Signal Scout after it is
mounted, to ensure proper bonding of the pressure-sensitive
adhesive with the target structure.
Figure 5-4: Adhesive Adapter Mounting

Screw Mounting

Perform the below instruction for screw mounting on the target
structure:
1. Insert the M6 socket head cap screw into the hole provided on the
screw-mount adapter (where the head of the screw sits inside the
adapter and the shank protrudes outwards).
2. Insert the protruding M6 socket head cap screw (with adapter) into
the hole provided on the target structure/bracket, and then secure
the adapter with M6 nut (on the other side of structure/bracket)
using Allen key and spanner (of required size). Ensure a Torque of
16 N-m or 140 in-lbs is applied for tightening.
Or, If there is an existing M6 tapped hole on the target structure,
then you just need to insert the protruding M6 socket head cap
screw (with adapter) into that hole provided on the target
structure/bracket, and tighten with Allen key (of required size).
23