2 Stage Thermostat, 1 Stage AHU
AHU Control Unit (ACU)
Thermostat
Input
Y1
Y1
Y2
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
C
DIP SW1
1
2
2 Stage Thermostat, 2 Stage AHU
AHU Control Unit (ACU)
Thermostat
Input
Y1
Y1
Y2
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
C
DIP SW1
1
2
18 English
AHU + Electric Heat with Heat Pump Configuration (continued)
Indoor unit
Output
Y1
Y
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
R
C
C
on
off
3
4
5
6
7
8
AHU + Electric Heat (emergency heat) with Heat Pump Configuration
Indoor unit
Output
Y1
Y1
Y2
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
R
C
C
on
off
3
4
5
6
7
8
Please review the Option Settings section for
additional system option settings.
If an auxiliary heater is installed and the heater
can operate simultaneously with the heat-pump,
configure the thermostat as a 2 stage heat pump
and configure the 4-way reversing valve to B. If a W1
or W2 signal is input, the heat-pump and auxiliary
heater can operate simultaneously.
NOTE
If the indoor unit only has a Y input terminal, connect
it to the Y1 output terminal in the Indoor section of
the AHU Control Unit (ACU).
Connection of the dehumidification (D) terminal is
optional. If the thermostat and the AHU/furnace
supports a dehumidification signal, the outdoor unit
and AHU Control Unit (ACU) will adjust operation to
optimize dehumidification.
Connection of the dehumidification (D) terminal is
optional. If the thermostat and the AHU/furnace
supports a dehumidification signal, the outdoor unit
and AHU Control Unit (ACU) will adjust operation to
optimize dehumidification.