Samsung MXD-U000XN Installation Manual page 16

Ahu control unit (acu)
Hide thumbs Also See for MXD-U000XN:
Table of Contents

Advertisement

Installation
1 Stage Thermostat, 1 Stage AHU
AHU Control Unit (ACU)
Thermostat
Input
Y
Y1
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
C
DIP SW1
1
2
2 Stage Thermostat, 1 Stage AHU
AHU Control Unit (ACU)
Thermostat
Input
Y1
Y1
Y2
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
C
DIP SW1
1
2
16 English
AHU with Cooling-only Configuration (continued)
Indoor unit
Output
Y1
Y
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
R
C
C
on
off
3
4
5
6
7
8
Indoor unit
Output
Y1
Y
Y2
G
G
W1
W1
W2
W2
D
D
O/B
O/B
R
R
C
C
on
off
3
4
5
6
7
8
Please review the Option Settings section for
additional system option settings.
If the system is used as cooling-only and there is no
auxiliary heater, configure the thermostat as 2 stage,
cooling-only system. If a W1 or W2 signal is input, the
air-conditioner turns off.
If the indoor unit only has a Y input terminal, connect
it to the Y1 output terminal in the Indoor section of
the AHU Control Unit (ACU).
Use the key switch on the outdoor unit to select
Cooling only before using the system.
Connection of the dehumidification (D) terminal is
optional. If the thermostat and the AHU/furnace
supports a dehumidification signal, the outdoor unit
and AHU Control Unit (ACU) will adjust operation to
optimize dehumidification.