Startup Instructions - Excalibur EWS SD130 Installation And User Manual

Water softener 1” duplex alternating
Table of Contents

Advertisement

SOFTENER INSTALLATION AND USER GUIDE
2.5)

Startup Instructions

Plug in transformers of both valves to wall socket.
Pour some water in brine tank so that water level reaches air check valve.
One control valve must show status "Standby" and other one must displays the time of day.
Press and hold "REGEN" button on valve which shows time of day.
This valve must initiate the immediate regeneration while other valve becomes online showing
time of day. The MAV motor starts turning to change the flowing port.
Slowly turn the inlet side handle of bypass valve halfway, the air must exit through the drain for
first few minutes.
When drain water flows steady, turn the inlet side handle of bypass valve fully open. Allow the
backwash cycle to run for at least 3 minutes with full opened inlet.
Press the "REGEN" button once to advance the regeneration to brine cycle. Confirm the water
suction in brine line by lifting the brine tank cover.
Press the "REGEN" button again to advance the regeneration to 2
When the countdown for 2
regeneration to rinse cycle.
Allow the valve to run rinse cycle for full amount of time.
When valve automatically advances to fill cycle, check for leaks and then press the REGEN
button to finish the regeneration.
Fully open the outlet side of the bypass valve, then open the test port downstream of this valve.
Confirm the "SOFTENING" blinking on display to verify the meter working. Shut off the test port
when water comes clear out of it.
Now press and hold REGEN button on other valve to start the regeneration.
Follow the above given sequence for regeneration in backwash cycle, brine cycle, 2
cycle and rinse cycle.
Check for leaks during fill cycle and let the fill cycle to run for full amount of time so that valve
can fill correct amount of water in brine tank to dissolve salt.
BARRIE • ONTARIO • CANADA TF: 705.733.8900 WWW.EXCALIBURWATER.COM
nd
backwash starts, press the REGEN button again to advance the
nd
Backwash cycle.
Backwash
nd
17