SOFTENER INSTALLATION AND USER GUIDE
1) INSTALLATION
1.1)
Pre-installation instructions
The cycle times, sequence of cycles, salt dose refill time and exchange capacity are preset to default by
OEM. The dealer must guide the installer to change the values according to the hardness, day override
and time of regeneration.
WATER TEST
Hardness
Iron
pH
*Nitrates
Manganese
Sulphur
Total Dissolved Solids
Installer must program the valve to recommended hardness, Day override and time of regeneration. Set
time of day, read normal operating displays, read power loss and error displays.
1.2)
General Installation and Service Warnings
The softener is designed so that it can be installed easily with minor plumbing changes on
•
previous plumbing.
The piping must be clamped properly and the weight of the plumbing must not be on the
•
softener.
•
Do not use any kind of lubricant including silicone. A silicone based lubricant can be only used on
O- Rings but not necessary.
•
The nuts and caps can be fastened and unfastened by hand or the plastic service wrench. Do not
use pipe wrench to tighten the caps and nuts.
1.3)
Site Requirements
Water Pressure: - 40-110 psi
•
•
Water Temperature: - 40-110°F (4.4-43°C)
Electrical- 115/120 V, 60Hz Uninterrupted Outlet
•
•
Current required is 0.5 Amperes
The plug-in transformer is for dry locations only
•
•
The tank should be on a firm level surface
BARRIE • ONTARIO • CANADA TF: 705.733.8900 WWW.EXCALIBURWATER.COM
gpg
ppm
number
ppm
ppm
yes/no
3