SOFTENER INSTALLATION AND USER GUIDE
2.6)

Configuration Settings

EXIT TO DISPLAY SCREENS
BARRIE • ONTARIO • CANADA TF: 705.733.8900 WWW.EXCALIBURWATER.COM
Step 1CS – Press NEXT and ▼ simultaneously for 5 seconds and
release. Press NEXT and ▼ simultaneously for 5 seconds and release. If
the screen in Step 2CS does not appear, the lock on the valve is
activated. To unlock, press ▼, NEXT, ▲ and REGEN in sequence, then
press NEXT and ▼ simultaneously for 5 seconds and release. Press
NEXT and ▼ simultaneously for 5 seconds and release.
Step 2CS – Use ▲ or ▼ to select 1.0 for 1" valve.
Step 3CS – Selecting the use of an outside signal to initiate a
regeneration. Selection only matters if a connection is made to the two
pin connector labeled DP SWITCH located on the printed circuit board.
Select oFF - feature not used. Other options are described below.
on0 – If the dP switch is closed for an accumulative time of 2 minutes a
regeneration will be signaled to the unit.
dEL – If the dP switch is closed for an accumulative time of 2 minutes a
regeneration will occur at the scheduled delayed regeneration time.
HoLd – If the dP switch is closed a regeneration will be prevented from
occurring while there is switch closure.
Press NEXT to go to Step 4CS. Press REGEN to return to previous step.
Step 4CS – Select the first unit as "UNIT A" and second unit as "UNIT B".
Register units A or B according to the plumbing of MAV and wiring on PC
boards. (See section MAV)
remaining capacity of online unit is less than 10% of total capacity. Press
NEXT to exit OEM Configuration Setup. Press REGEN to return to previous
step.
Step 5CS – Select delay "OFF" for rinse
and fill cycle. The rinse and fill cycles of
regeneration can be delayed until the
18