Solar usage guide
NOTE: For additional details and specifications on solar usage, please refer to liftmaster.com.
System voltage
Control board with no radios programmed
®
One or more LiftMaster
remote controls programmed
®
myQ
device or wireless dual gate programmed
Expansion board
Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board)
NOTE: The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications.
BATTERY
CURRENT
DRAW
(mA)
6
25
10W SOLAR
30
PANEL
50
100
6
20W SOLAR
25
PANEL (Two
10W 12V
30
panels in
100
parallel)
200
6
30W SOLAR
25
PANEL
(Three 10W
30
12V panels
100
in parallel)
200
All numbers are estimates. Actual results may vary.
Typical System Standby Battery Current Consumption (mA)
Add up current draw by feature and accessory to determine total current draw
SOLAR GATE CYCLES PER DAY
ZONE 1
7AH
Two 7AH
33AH
batteries
batteries
batteries
41
46
34
39
33
37
26
30
11
14
50
50
50
50
50
50
42
50
25
50
50
50
50
50
50
50
50
50
24
APPENDIX
ZONE 2
7AH
Two 7AH
batteries
batteries
48
24
27
41
18
21
39
17
19
32
11
13
16
50
47
50
50
50
40
50
50
38
50
15
26
34
50
50
50
50
50
50
50
49
50
50
25
50
17
50
44
ZONE 3
33AH
7AH
Two 7AH
batteries
batteries
batteries
29
22
21
15
50
19
50
13
50
12
32
50
24
50
18
50
16
50
30
12V
4.2 mA
+1.5 mA
+3.9 mA
+18.5 mA
+6.6 mA
33AH
batteries
11
11
24
27
18
21
17
20
37
44
30
37
28
35
13