SYMPTOM
POSSIBLE CAUSES
Gate closes, but
a. Vehicle loop detector active
will not open.
b. Low battery with LOW BATT option set to
CLOSE
Obstruction in
a. Force adjustment needed
gate's path does not
cause gate to stop
and reverse.
Photoelectric
a. Incorrect photoelectric sensor wiring
sensor does not
b. Defective photoelectric sensor
stop or reverse
gate.
Edge Sensor does
a. Incorrect edge sensor wiring
not stop or reverse
b. Defective edge sensor
gate.
Alarm sounds for 5
a. Double entrapment occurred (two obstructions
minutes or alarm
within a single activation)
sounds with a
command.
Alarm beeps three
a. Low battery
times with a
command.
On dual-gate
a. Incorrect Bipart switch setting
system, incorrect
gate opens first or
closes first.
Alarm beeps when
a. Expansion board setting
running.
b. Constant pressure to open or close is given
Maglock not
a. Maglock wired incorrectly
working correctly.
Solenoid lock not
a. Solenoid wired incorrectly
working correctly.
Switched (SW)
a. In limit setup mode
Accessory power
remaining on.
Accessories
a. Normal behavior
connected to Switch
(SW) Accessory
power not working
correctly, turning
off, or resetting.
TROUBLESHOOTING
SOLUTIONS
a. Check all vehicle detector inputs for an active detector
b. Check if AC power is available. If no AC power, then running on
a. Refer to the Adjustment section to conduct the obstruction test
a. Check photoelectric sensor wiring. Retest that obstructing
b. Replace defective photoelectric sensor. Retest that obstructing
a. Check edge sensor wiring. Retest that activating edge sensor
b. Replace defective edge sensor. Retest that activating edge
a. Check for cause of entrapment (obstruction) detection and
a. Check if AC power is available. If no AC power, then running on
a. Change setting of both operator's Bipart switch settings. One
a. Pre-warning is set to "ON"
b. Constant pressure to open or closed is given
a. Check that Maglock is wired to N.C. and COM terminals. Check
a. Check that Solenoid is wired to N.O. and COM terminals. Check
a. Learn the limits
a. Move accessory to accessory power "ON"
38
batteries and battery voltage must be 11.5 Vdc or higher. Charge
batteries by AC or solar power or replace batteries.
and perform the proper force adjustment that is needed.
photoelectric sensor causes moving gate to stop, and may
reverse direction.
photoelectric sensor causes moving gate to stop, and may
reverse direction.
causes moving gate to stop and reverse direction.
sensor causes moving gate to stop and reverse direction.
correct. Press the reset button to shut off alarm and reset the
operator.
batteries and battery voltage must be 11.5 Vdc or higher. Charge
batteries by AC or solar power or replace batteries
operator should have Bipart switch ON (operator that opens
second) and the other operator should have Bipart switch OFF
(operator that opens first).
that Maglock has power (do not power maglock from control
board accessory power terminals). If shorting lock's NO and
COM wires does not activate Maglock, then replace Maglock or
Maglock wiring (refer to Wiring Diagrams).
that Solenoid has power (do not power solenoid from control
board accessory power terminals). If shorting lock's NC and
COM wires does not activate Solenoid, then replace Solenoid
lock or Solenoid wiring (refer to Wiring Diagrams).