Carrier Performance 25HPA6 Wiring Diagram

2 stage heat pump with puronr refrigerant 2 to 5 nominal tons
Hide thumbs Also See for Performance 25HPA6:

Advertisement

Quick Links

25HPA6
Performancet Series 2---Stage Heat Pump
with Puronr Refrigerant
2 to 5 Nominal Tons
CS
BLU
RED
BRN
230V
BLK
CCH
BLK
BLK
L1
208/230 1Ø
11 21
L2
POWER
23 23
SUPPLY
C C
EQUIP GND
CONT
RED/WHT
BRN/YEL
YEL/PNK
2
YEL/PNK
1
PL2
LPS
RED
RED
2
1
DTS
RED
PL3
3
BLU/PNK
BLU/PNK
1
HPS
PL4
T1
BRN
4
C
BRN/YEL
3
LO
RED/WHT
2
1
BLU
HI
PL5
OPTIONAL
NON-COMMUNICATING
CONTROL
PL7
SEE NOTE #10
R C W1 Y1 Y2 O
TO INDOOR UNIT
LEGEND
FACTORY POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
COMPONENT CONNECTION
FIELD SPLICE
JUNCTION
CAPACITOR
CAP
CB
CIRCUIT BOARD
CRANKCASE HEATER
CCH
CHS
CRANKCASE HEATER SWITCH
SYSTEM COMMUNICATION
COMM
COMP
COMPRESSOR
CONTACTOR
CONT
* MAY BE FIELD INSTALLED
UNIT OPERATION
This control board contains a five minute short cycle protector. A five minute delay will
occur between compressor off/on cycles. To bypass delay, short forced defrost pins
for 1 second then release. The crankcase heater is energized during off cycle below 65ºF.
Defrost time selection - (shown as DT on board) the defrost interval time can be field
selected, dependent upon local georgraphic requirements. It is factory set at 90 minutes
and can be changed to either 30, 60 or 120 minutes.
Defrost - defrost will only be performed at outdoor temperatures less than 50ºF defrost
will initiate when time selected has elapsed and the coil temperature is less than 32ºF
(+/-2º) And will terminate at 65ºF (+/-5º) upon defrost termination the outdoor fan will delay
20 Seconds before starting.
Field initiated forced defrost - (shown as forced defrost on board) by placing a jumper
across the forced defrost terminals for 5 seconds, or longer, and then removing the
jumper the unit will initate a defrost cycle regardless of coil temperature the defrost
cycle will terminate at 65ºF (+/-5º) if coil termperature is above 32ºF or outdoor ambient
temperature is above 50ºF, defrost mode will terminate after 30 seconds of active mode.
Wiring Diagram
CONNECTION DIAGRAM
RED
TRAN
24V
CAP
F
COM
C
208V
YEL
CHS
H
BLK
VIO
BLK
BLK
YEL
YEL
YEL
YEL
BLU
L2
L1 ODF
CCH
VS
VR
VIO BLK
RED
BLU
BRN
YEL
CB
PL1
C
TIME
DEFROST
RVS
(MIN)
TIME
SEV
C
SR
LED
LED
ON
OFF
OCT
QUIET
(DEFAULT)
SHIFT
COMM STATUS
OAT
AS PROVIDED
BY MANUFACTURER
SEE NOTE #11
A B C D
FORCED
R C
W1
Y2 O
Y1
DEFROST
MODEL PLUG
* UC (WITH INFINITY/EVOLUTION ONLY)
CONNECT TO
R AND Y2 ON
CONTROL BOARD
COMP HIGH CAP SOLENOID
CS
DTS
DISCHARGE TEMP SWITCH
HIGH PRESSURE SWITCH
HPS
LPS
LOW PRESSURE SWITCH
LIQUID SOLENOID
* LS
OAT
THERMISTOR (OUTDOOR AIR)
THERMISTOR COIL
OCT
OFM
OUTDOOR FAN MOTOR
REVERSING VALVE SOLENOID
RVS
START CAPACITOR
SC
SEV
SOLENOID EXPANSION VALVE
START RELAY
SR
STATUS
SYSTEM FUNCTION LIGHT
TRANSFORMER
TRAN
* UC
UTILITY CURTAILMENT
Fig. 1 – Wiring Diagram — Model sizes 2 - - 5 tons, 208/230- -1
SCHEMATIC DIAGRAM (LADDER FORM)
L1
CCH
COMP
C R
S
CONT
BRN
11
21
EQUIP
BLU
GND
YEL
OFM
BLK
2
1
LPS
YEL
PL2
2
PWM1
1
DTS
PWM2
PL3
3
SR
RVS
BLU
1
HPS
PL4
1
ORG
T1
4
2
C
ORG
3
3
LO
2
4
CONT
HI
1
OCT
CS
PL5
BY MANUFACTURER
1
BRN
A B C D
PL7
2
BRN
OPTIONAL
3
NON-COMMUNICATING
4
BLK
CONTROL
5
SEE NOTE #10
PL6
OAT
BLK
R C W1 Y1 Y2 O
P8
*LS
060
FLASH
FAULT DEFINITION
CODE
On, No Flash Standby
Low Stage
1, Pause
High Stage
2, Pause
3, Pause
ODU Fan Delay Defeat Not Active
4, Pause
ODU Fan Delay Defeat Active
5, Pause
Brown Out is Disabled
6, Pause
Brown Out is Active
System Communications Failure
16
Invalid Model Plug
25
High Pressure Switch Trip or
31
Disch Temp Switch Trip
32
Low Pressure Switch Trip
Control Fault
45
Brown out (230V)
46
Short flashes indicate the first digit in the status code, followed by long flashes indicating the second digit of
the status code.
NOTES:
1. Compressor furnished with inherent thermal protection.
2. To be wired in accordance with National Electric Code (N.E.C.) and local codes.
3. Outdoor unit control requires a minimum of 27 va, 24 vac control power.
4. Use copper conductors only. Use conductors suitable for at least 70ºC (167ºF).
5. If indoor section has a transformer with a grounded secondary, connect the grounded side to "C".
6. If any of the original wire, as supplied, must be replaced, use the same or equivalent wire.
7. Check all electrical connections inside control box for tightness.
8. Do not attempt to operate unit until service valves have been opened (Back Seated).
9. MUST USE THERMOSTAT OR USER INTERFACE LISTED IN PRE-SALE LITERATURE ONLY.
10. In case of non-communicating indoor system disconnect factory provided wires from A, B, C, and D
terminals. Use factory provided wires to connect to R, C, W1, Y1, Y2, and O as required by
installation instructions. Cap or remove unused factory provided wires.
11. For communicating control only.
TRAN 230V
CHS
CONT
C
230V
23
R
CAP
C
F
S
COMP
C
H
OFM
VS
VR
L2
L1 ODF CCH
YEL
PWM1
VIO BLK RED
BLU
BRN
YEL
PWM2
CB
BLU
PL1
C
1
RVS
2
TIME
DEFROST
3
SEV
(MIN)
TIME
C
4
LED
LED
1
OCT
2
ON
3
OFF
QUIET
OAT
4
(DEFAULT)
COMM STATUS
SHIFT
5
AS PROVIDED
PL6
SEE NOTE #11
FORCED
P8
R C
Y2 O
DEFROST
W1
Y1
MODEL PLUG
TO INDOOR UNIT
MODEL PLUG CHART
CONTROL
BOARD
TRAN
47
18
360
FLASH
FAULT DEFINITION
CODE
47
No 230v with call to run
53
Outdoor Air Temp Sensor
55
Coil Temp Sensor
Temp Sensor Range Error
56
71
Low Stage Thermal Cutout
72
High Stage Thermal Cutout
73
Contactor Shorted
74
Contactor Open (No 230v to Comp)
81
Low Stage thermal lockout (4 HRS)
82
High Stage thermal lockout (4 HRS)
83
Low pressure lockout (4 HRS)
84
High pressure lockout (4 HRS)
338054-101 REV. B