Carrier Infinity 25HNB6 Product Data

Carrier Infinity 25HNB6 Product Data

2-stage heat pump with puron refrigerant 2 to 5 nominal tons
Hide thumbs Also See for Infinity 25HNB6:

Advertisement

25HNB6
Infinityt16 2---Stage Heat Pump
with Puronr Refrigerant
2 to 5 Nominal Tons
Carrier's heat pumps with Puronr refrigerant provide a collection
of features unmatched by any other family of equipment. The
25HNB6 has been designed utilizing Carrier's Puron refrigerant.
The environmentally sound refrigerant allows consumers to make a
responsible decision in the protection of the earth's ozone layer.
This product has been designed and manufactured to meet Energy
Starr criteria for energy efficiency when matched with appropriate
coil components. Refer to the combination ratings in the Product
Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time.
Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

Energy Efficiency
S 13.5 - - 17.2 SEER/11.0 - - 13.5 EER/8.0 - - 9.6 HSPF
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 67 dBA
S Quiet mount split post compressor grommets
S Forward- -swept condenser fan blade
S Compressor sound hood
S Laminated steel compressor mounting plate
S 8 pole PSC ball bearing outdoor condenser fan motor
Comfort
S System supports Infinity Controlt or standard 2- -stage
thermostat controls

Reliability

S Puronr refrigerant - - environmentally sound, won't deplete the
ozone layer and low lifetime service cost.
S Front- -seating service valves
S 2- -stage scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S High pressure switch
S Loss of charge switch
S Filter drier
S Balanced refrigeration system for maximum reliability
S Crankcase heater standard

Durability

WeatherArmort protection package:
S Solid, Durable sheet metal construction
S Steel louver coil guard
S Baked- -on, complete outer coverage, powder paint
Controls and Diagnostics
S Infinityt Control or Thermostat
S Utility Interface Connection
S Up to 83 point diagnostic capability with Infinityt Control
Applications
S Long- -line - - up to 250 feet (76.2 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)
INDUSTRY LEADING

FEATURES / BENEFITS

Advertisement

Table of Contents
loading

Summary of Contents for Carrier Infinity 25HNB6

  • Page 1: Product Data

    S Loss of charge switch S Filter drier S Balanced refrigeration system for maximum reliability Carrier’s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The S Crankcase heater standard 25HNB6 has been designed utilizing Carrier’s Puron refrigerant.
  • Page 2: High Pressure Switch

    MODEL NUMBER NOMENCLATURE Product Product Major Cooling Minor Tier SEER Variations Open Open Voltage Series Family Series Capacity Series 1,000 Btuh 0=Not 0=Not 25 = HP H = RES HP B = Puron 6=16 SEER A = Standard 3=208/230--- 1 0, 1, 2...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE SERIES 24--- 30 36--- 30 48--- 30 60--- 30 Operating Weight lb (kg) 314 (142) 316 (143) 316 (143) 372 (169) Shipping Weight lb (kg) 358 (162) 360 (163) 360 (163) 417 (189) Compressor Type Ultratechr Scroll REFRIGERANT Puron®...
  • Page 4: Refrigerant Piping Length Limitations

    REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH{...
  • Page 5 ACCESSORIES KIT NUMBER KIT NAME 24--- 30 36--- 30 48--- 30 60--- 30 KHALS0401LLS SOLENOID VALVE KHASS0606MPK* SNOW STAND KSAHS2301AAA HARD START KIT KSAHS2401AAA HARD START KIT KSAHS2501AAA HARD START KIT KSAHS2601AAA HARD START KIT KSASF0101AAA SUPPORT FEET KSATX0201PUR KSATX0301PUR KSATX0401PUR KSATX0501PUR x = Accessory S = Standard * Available from RCD...
  • Page 6 1. Compressor Start Assist - - Capacitor and Relay 4. Outdoor Air Temperature Sensor Start capacitor and relay gives a “hard” boost to compressor motor Designed for use with Carrier Thermostats listed in this at each start up. publication. This device enables the thermostat to display the outdoor temperature.
  • Page 7: Electrical Data

    ELECTRICAL DATA UNIT FUSE** OPER VOLTS* COMPR WIRE WIRE LENGTH LENGTH SIZE --- V/PH or CKT SIZE{ SIZE{ ft (m)} ft (m)} VOLTAGE, SERIES 60°C 75°C 60°C 75°C AMPS 24--- 30 52.0 12.7 16.5 48 (14.6) 45 (13.7) 36--- 30 82.0 16.7 21.8...
  • Page 10 MBTUH CAPACITY, HEATING INTEGRATED UNIT LOSS, HEAT BUILDING...
  • Page 11 MBTUH CAPACITY, HEATING INTEGRATED UNIT LOSS, HEAT BUILDING...
  • Page 12 Wall...
  • Page 63 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM HEAT PUMP 25HNB6 GENERAL 2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed, 1- -phase type with class B insulation and permanently lubricated. Outdoor- -mounted, air- -cooled, split- -system heat pump unit suitable for ground or rooftop installation.
  • Page 64 10. Do not apply capillary tube indoor coils to these units. 11. Factory- -supplied filter drier must be installed. Catalog No: 25HNB6---1PD Copyright 2011 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 05/11 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.