Twisted Pair Backbone, Twisted Pair To-The-Desk; Unshielded Twisted Pair Network - 3Com CoreBuilder 5000 User Manual

Ethernet 24-port 10base-t module
Hide thumbs Also See for CoreBuilder 5000:
Table of Contents

Advertisement

2-8
D
ESIGNING AND
Twisted Pair
Backbone, Twisted
Pair To-The-Desk
E
N
XPANDING THE
ETWORK
In constructing a twisted pair backbone, remember the following rule:
There can be no more than eight 24-Port modules in the path
between any two transceivers due to Ethernet's four-repeater rule.
This is because each 24-Port module counts as a 1/2 repeater unless
the signal goes in one port and out another port of the same
module, in which case the module counts as a full repeater.
You must add a bridge if you have more than eight 24-Port modules
serially connected. Each bridge creates a subnetwork. Each
subnetwork can have its own 4200 meter network diameter.
The configuration in
twisted-pair network using 24-gauge cable.
100 m
Figure 2-2

Unshielded Twisted Pair Network

Figure 2-2
illustrates a possible unshielded
B
100 m
C
100 m
A
100 m
D
50 m

Advertisement

Table of Contents
loading

Table of Contents